HP ProLiant 3000 ProLiant 3000 Servers Maintenance and Service Guide - Page 82
Hard Drive Test Error Codes, Table 3-11
View all HP ProLiant 3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
3-25 Hard Drive Test Error Codes The 1700 series of Diagnostic error codes identifies failures with hard drives, hard drive controller boards, hard drive cabling, and system board functions. If your system uses a drive array controller, see the section for Drive Array Advanced Diagnostics (DAAD). Table 3-11 Hard Drive Test Error Codes Error Code 1700-xx 1701-xx 1702-xx 1703-xx 1704-xx 1705-xx 1708-xx Description Fixed disk ID drive types test failed. Fixed disk format test failed. Fixed disk read test failed. Fixed disk write/read/compare test failed. Fixed disk random seek test failed. Fixed disk controller test failed. Fixed disk format bad track test failed. Recommended Action 1. Run the System Configuration Utility and verify the drive type. 2. Replace the fixed disk drive signal and power cables and retest. 3. Replace the fixed disk drive controller and retest. 4. Replace the fixed disk drive and retest. 5. Replace the system board and retest. 1709-xx Fixed disk reset controller test failed. 1710-xx Fixed disk park head test failed. 1715-xx Fixed disk head select test failed. 1716-xx Fixed disk conditional format test failed. 1717-xx Fixed disk ECC* test failed. 1719-xx Fixed disk drive power mode test failed. 1736-xx Drive Monitoring failed. 1799-xx Invalid fixed disk drive type failed. * Error Checking and Correcting Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide