HP ProLiant 3000 ProLiant 3000 Servers Maintenance and Service Guide - Page 136
System Unit, Table 5-1, System Unit Specifications - btu
View all HP ProLiant 3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 136 highlights
5-2 Physical and Operating Specifications System Unit Dimensions Height Depth Width Weight (Model 1, U.S.) Input Requirements Rated Input Voltage Rated Input Frequency Rated Input Current Power Supply Output Power Rated Steady-State Power Maximum Peak Power Temperature Range Operating Non-operating Relative Humidity (noncondensing) Operating Nonoperating Maximum Wet Bulb Temperature Heat Dissipation Table 5-1 System Unit Specifications U.S. Metric 20.5 in 24.5 in 12.7 in 75 lbs Low range 100 to 120 V 50 to 60 Hz 8 A Low range 500 W 540 W 52.1 cm 62.2 cm 32.3 cm 34 kg High range 200 to 240 V 50 to 60 Hz 6 A High range 750 W 780 W 50° to 95°F -20° to 140°F 10° to 35°C -30° to 60°C 20% to 80% 5% to 90% 101.7°F 2594 BTU/h 20% to 80% 5% to 90% 38.7°C 3754 BTU/h