HP ProLiant 3000 ProLiant 3000 Servers Maintenance and Service Guide - Page 137

Power Supply, Table 5-2, Power Supply Specifications

Page 137 highlights

5-3 Power Supply Input Specifications Nominal Line Voltage Range Input Line Frequency Range Power Factor Input Current Inrush Current Holdup Time General Specifications Full Output Rating Minimum Load Ambient Temperature Range Operating Storage Dielectric Voltage Withstand Input to Output Input to Ground Common and Differential Mode (superimposed on AC line) Table 5-2 Power Supply Specifications U.S. Metric 100 to 120 VAC 90 to 132 VAC 47 to 63 Hz 0.95 8 A at 100 VAC

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162

5-3
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide
Power Supply
Table 5-2
Power Supply Specifications
U.S.
Metric
Input Specifications
Nominal Line Voltage
100 to 120 VAC
200 to 240 VAC
Range Input Line
90 to 132 VAC
180 to 270 VAC
Frequency Range
47 to 63 Hz
47 to 63 Hz
Power Factor
0.95
0.95
Input Current
8 A at 100 VAC
6 A at 200 VAC
Inrush Current
<150 A at 132 VAC (cold start)
<150 A at 132 VAC (cold start)
Holdup Time
20 ms from zero crossing at 120 VAC
20 ms from zero crossing at 240 VAC
General Specifications
To 104
°
F and 5,000 ft
To 40
°
C and 1,524 m
Full Output Rating
To 90
°
F and 10,000 ft
To 32
°
C and 3,048 m
(derate linearly)
Minimum Load
1.0 A on + 5 V output
1.0 A on +12 V output
0.5 A on +3.3 V output
1.0 A on + 5 V output
1.0 A on +12 V output
.5 A on +3.3 V output
Ambient Temperature Range
Operating
50
°
to 104
°
F
10
°
to 40
°
C
Storage
-40
°
to 149
°
F
-40
°
to 65
°
C
Dielectric Voltage Withstand
Input to Output
3000 VAC/min
3000 VAC/min
Input to Ground
1500 VAC/min
1500 VAC/min
Common and Differential Mode
(superimposed on AC line)
2500V, 1
μ
s, damped sinusoid 600 V, 10
μ
s pulse 20% step change in AC input
voltage