HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 127
Installing the Disk Enclosures, Step 1: Collect Required Tools, Step 2: Unpack the Product
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 127 highlights
Installing the Disk Enclosures Installation Disk enclosures should be installed in the rack starting at the bottom and proceeding upward. When all disk enclosures are installed, the controller enclosure is installed at the top, directly above the disk enclosure. Installation instructions for the disk enclosure SC10 are provided below; installation instructions for the controller enclosure FC60 follow this section. Step 1: Collect Required Tools • Torx T25 screwdriver • Torx T15 screwdriver • Small flat-blade screwdriver Step 2: Unpack the Product 1. Lift off the overcarton and verify the contents of the box (see Table 16 and Figure 47). Table 16 Disk Enclosure SC10 Accessories Figure Label A B C D E F G H I Part (part number) Disk Enclosure (with power supplies, fans, and BCC modules) Rail kit (A5251A) for System/E cabinets Rail kit (A5656A) for Rittal racks Rack filler panel, 1/2 EIA Unit, 1 ea. Disks or fillers (A5234A or A5235A), pack of 10 SCSI terminators, 2 ea. Power cords, 2ea ESD strap (9300-2170), 1 ea. Documentation Installing the Disk Enclosures 127