DC Power Harnesses,
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 350 highlights
DC Power Harnesses The controller enclosure contains three DC Power harnesses (Figure 121): two +5 VDC and one +12 VDC. The power harnesses provide power connections between the power interface board and the controller enclosure backpanel (midplane). Removal and replacement of these harnesses requires removal of the controller enclosure from the rack. To replace the DC power harnesses, complete the following steps: +5 VDC Power Harnesses +12 VDC Power Harness Figure 121 DC Power Harnesses 1. Remove the controller enclosure from the rack. See "Controller Enclosure" on page 342. 2. Remove the harness cover plate. See "Harness Cover Plate" on page 349. 3. Disconnect the harness connectors from both the controller rear shield and the power supply cage/midplane assembly and remove the cable(s) from the enclosure. 350 Internal Controller Enclosure Assemblies