HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 227
Errors During / After Firmware Download, Table 29
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 227 highlights
Troubleshooting Errors During / After Firmware Download Different patterns are displayed after downloading firmware. The patterns are shown in Table 29. Note Note that a ! indicates the LED is On or Flashing. . Table 29 Firmware Download LEDs Error Download file is lacking header record. LED Pattern 0x61 Download file header fails checksum test. 0x64 Download file header contains unexpected download type. 0x65 The user should attempt to download a known good file. 0x67 Intermodule error call to flash function passed bad flash type. There is a mismatch between the Boot Firmware and the Application Firmware. The user must download matched versions of both controller Bootware and controller Application Firmware. Invalid address in flash device. 0x91 0x92 Unable to fully erase boot flash segments (bad voltage or device). Replace the controller board. Unable to fully erase file flash segments (bad voltage or device). Replace the controller board. Unable to program boot flash after 3 cycles of erase and write. Replace the controller board. Unable to program application file flash after 3 cycles of erase and write. Replace the controller board. Software load failure. There is a mismatch between the Boot Firmware and the Application Firmware. The user must download matched versions of both code types. 0x95 0x96 0x97 0x98 0xE6 Controller Enclosure Troubleshooting 227