Troubleshooting Table 30 Controller Status LEDs codes (cont'd) Code Description Comments Cause / Solution 0x91 0x92 0x93 0x95 0x96 0x97 0x98 0xA1 Intermodule error call to flash function passed bad flash type Firmware file is bad / Download Firmware with a good file. Attempt to download Firmware again. If the problem persists, replace the controller module. Invalid address in flash device Length too long for flash device Firmware file is bad / Download Firmware with a good file. Attempt to download Firmware again. If the problem persists, replace the controller module. Unable to fully erase boot flash segments Controller module / reseat or replace Unable to fully erase file flash segments Unable to program boot flash after 3 cycles of erase and write Unable to program application file flash after 3 cycles of erase and write Start Boot Firmware Boot Funct. Status 0xA2 Initialize core hardware 0xA3 Determine hardware configuration 0xA4 Determine CDC memory size 0xA5 0xA6 Determine RAID Parity Assist memory size Initialize BIOS timer 0xA7 Initialize serial interface 0xA8 General software initialization 0xA9 Display Boot banner 0xAA Test Boot Menu invocation 0xAA (steady) PCI fatal fault 0xAB Test Boot Menu memory Boot Funct. Status Memory problem / reseat or replace Controller Enclosure Troubleshooting 233