HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 230
Description, Comments, Cause / Solution
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 230 highlights
Table 30 Controller Status LEDs codes (cont'd) Code Description Comments 0x36 0x00 Processor DRAM diagnostics running HW Diag. status 0x37 0x00 RPA DRAM diagnostics running 0x38 0x00 Processor Level 2 Cache diagnostics running 0x44 0x01 CDC diagnostics running 0x44 0x02 SIO diagnostics running 0x44 0x03 RPA diagnostics running 0x44 0x12 SIO Interrupt diagnostics running 0x54 0x00 ICON diagnostics running 0x55 0x00 FReD diagnostics running 0x61 0x64 0x65 0x65 0x00 Download file is lacking header record Download file header fails checksum test Download file header contains unexpected download type Host SCSI Channel (53C825) diagnostics running 0x65 0x10 Host SCSI Channel (53C875) diagnostics running 0x65 0x20 Host Fibre Channel Interface diagnostics running 0x67 CRC failure on downloaded data Cause / Solution Controller module / reseat or replace Firmware file is bad / Download Firmware with a good file. Controller module / reseat or replace 230 Controller Enclosure Troubleshooting