HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 234
Controller module, reseat or replace, Memory problem, Rebooting after Boot Firmware
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 234 highlights
Table 30 Controller Status LEDs codes (cont'd) Code Description 0xAC Load Boot Menu Comments Boot Funct. Status 0xAD 0xAE 0xAF 0xB0 Invoke Boot Menu Exit Boot Menu Test Diagnostics Manager memory Load Diagnostics Manager 0xB1 Invoke Diagnostics Manager 0xB2 0xB3 0xB4 0xB5 0xB6 0xB7 0xB8 0xB9 0xBE 0xBF 0xE3 0xE4 0xE5 Clear work memory Clear extended memory Kernel set-up Enable Level 2 cache Load kernel Load network manager Load Application code symbol table Invoke kernel Unexpected return from kernel Rebooting after Boot Firmware download No host channel devices on the PCI bus Wrong number of drive channel devices on the PCI bus No RPA device on the PCI bus HW Init. status Cause / Solution Controller module / reseat or replace Memory problem / reseat or replace Controller module / reseat or replace Controller module / reseat or replace Memory problem Controller module / reseat or replace 234 Controller Enclosure Troubleshooting