HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 281
SureStore E Disk System SC10 Troubleshooting, Disk Enclosure LEDs
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 281 highlights
Troubleshooting SureStore E Disk System SC10 Troubleshooting The following steps should be performed in the indicated sequence when isolating problems with the Disk System SC10 enclosure: 1. Gather information from the following sources: - Hardware Event notifications - LED status indicators - Online status information and error logs (SAM/STM) 2. Isolate the cause of the problem. 3. Correct the problem. If it is necessary to replace a component, see "Removal and Replacement" on page 287. 4. Verify that the disk array is operational using IOSCAN or other host utilities. Disk Enclosure LEDs Figure 89 shows the locations of the disk enclosure status LEDs. Table 38 summarizes the operating LED states for all components within the disk enclosure. SureStore E Disk System SC10 Troubleshooting 281