HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 169
Installation, Module, Normal State
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 169 highlights
Installation Table 22 Normal LED Status for Controller Enclosure Module LED Normal State Controller Power On Enclosure Power Fault On (green) Off Fan Fault Off Controller Fault Off Fast Write Cache On (green) while data is in cache Controller Controller Power On (green) Controller Fault Off Heartbeat Blink (green) Status Green There are 8 status LEDs. The number and pattern of these LEDs depend on how your system is configured. Controller Fault - B Battery Full Charge - B Off On (green)1 Fault - A Off Full Charge - A On (green)1 Controller Power Assembly Power 1 Power 2 On (green) On (green) Controller Fan Assembly Fan Power Fan Fault On (green) Off 1. Both Full Charge A and Full Charge B LEDs are ON after batteries are fully charged. The LEDs flash while charging is in progress, and remain on when charging is complete. Any time power to the disk array controller enclosure is cycled, the BBU will recharge for 15 minutes. During this time, the Full Charge LEDs will flash. Applying Power to the Disk Array 169