HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 92
Six Disk Enclosure Configurations
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 92 highlights
Six Disk Enclosure Configurations High Availability/High Performance • Hardware Configuration - Two disk array controllers connected directly to host Fibre Channel adapters - Six disk enclosures with ten 73 GByte disks each (60 disks total) - Disk enclosures configured for full-bus mode (one SCSI channel per enclosure) • Volume Group Configuration - Ten RAID 0/1 volume groups, each comprising six disks (3+3) - Each disk in a volume group is in a separate enclosure • High Availability - Handles a single disk failure, single BCC failure, single channel failure, or a single controller failure • Disk Capacity - Maximum capacity 4380 GBytes - Usable capacity 2190 GBytes 92 Recommended Disk Array Configurations
92
Recommended Disk Array Configurations
Six Disk Enclosure Configurations
High Availability/High Performance
•
Hardware Configuration
–
Two disk array controllers connected directly to host Fibre Channel adapters
–
Six disk enclosures with ten 73 GByte disks each (60 disks total)
–
Disk enclosures configured for full-bus mode (one SCSI channel per enclosure)
•
Volume Group Configuration
–
Ten RAID 0/1 volume groups, each comprising six disks (3+3)
–
Each disk in a volume group is in a separate enclosure
•
High Availability
–
Handles a single disk failure, single BCC failure, single channel failure, or a single
controller failure
•
Disk Capacity
–
Maximum capacity 4380 GBytes
–
Usable capacity 2190 GBytes