HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 231
Table 30, Troubleshooting, Description, Comments, Cause / Solution
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 231 highlights
Troubleshooting Table 30 Controller Status LEDs codes (cont'd) Code Description Comments 0x6B 0x01 Drive SCSI Channel 1 (53C810) HW Diag. status diagnostics running 0x6B 0x02 Drive SC SI Channel 2 (53C810) diagnostics running 0x6B 0x03 Drive SCSI Channel 3 (53C810) diagnostics running 0x6B 0x04 Drive SCSI Channel 4 (53C810) diagnostics running 0x6B 0x05 Drive SCSI Channel 5 (53C810) diagnostics running 0x6B 0x11 Drive SCSI Channel 1 (53C825) diagnostics running 0x6B 0x12 Drive SCSI Channel 2 (53C825) diagnostics running 0x6B 0x13 Drive SCSI Channel 3 (53C825) diagnostics running 0x6B 0x14 Drive SCSI Channel 4 (53C825) diagnostics running 0x6B 0x15 Drive SCSI Channel 5 (53C825) diagnostics running 0x6B 0x21 Drive SCSI Channel 1 (53C875) diagnostics running 0x6B 0x22 Drive SCSI Channel 2 (53C875) diagnostics running 0x6B 0x23 Drive SCSI Channel 3 (53C875) diagnostics running 0x6B 0x24 Drive SCSI Channel 4 (53C875) diagnostics running 0x6B 0x25 Drive SCSI Channel 5 (53C875) diagnostics running Cause / Solution Controller module / reseat or replace Controller Enclosure Troubleshooting 231