HP Surestore Disk Array FC60 HP SureStore E Disk Array FC60 Service Manual (A5 - Page 235
Download Firmware, with a good file.
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 235 highlights
Troubleshooting Table 30 Controller Status LEDs codes (cont'd) Code Description Comments 0xE6 Software load failure 0xE7 0xE8 Kernel missing, or kernel CRC mismatch Application Firmware missing, or Application CRC mismatch 0xEA Swapped controller 0xF1 0xF2 0xF3 0xF4 0xF5 0xF7 0xF8 0xF9 0xFA 0xFB 0xFC 0xFF Processor set-up CDC chip set-up RAID Parity Assist chip set-up Memory Test Load Boot Firmware Clear Boot memory Enable Protected mode Memory test failure Exception error Start mode determination Invoke Boot Firmware Hardware reset HW Init. status Cause / Solution Firmware file is bad / Download Firmware with a good file. Controller is in wrong slot. Controller module / reseat or replace Hardware reset is in progress or there is a bad controller module. Controller Enclosure Troubleshooting 235