Set the disk Enclosure Tray ID switches. See, Disk Enclosure Tray ID Switch on,
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 179 highlights
Installation 8. Set the disk Enclosure (Tray) ID switches. See "Disk Enclosure (Tray) ID Switch" on page 142. a. Set the Enclosure ID switches on both BCC A and BCC B cards to identify the disk enclosure. The Enclosure ID switch setting must be the same for both BCC A and BCC B. b. The Enclosure ID switch settings are made as follows for the disk enclosures installed. The enclosure connected to channel 1 should be set to 0. The enclosure connected to channel 2 should be set to 1. The enclosure connected to channel 3 should be set to 2. The enclosure connected to channel 4 should be set to 3. The enclosure connected to channel 5 should be set to 4. The enclosure connected to channel 6 should be set to 5. 9. Move the necessary disks from the existing disk enclosures to the new enclosures. Refer to your expanded configuration drawing and the disk labels to determine the location of each disk that must be moved. Adding Disk Enclosures to Increase Capacity 179