Controller Enclosure Power Supply Fan Module Introduction This section describes procedures to troubleshoot the controller enclosure power supply fan module. See Figure 82. For troubleshooting procedures. refer to the "Master Troubleshooting Table" on page 275. Figure 82 Controller Enclosure Power Supply Fan Module Servicing Notes • When replacing the power supply fan module, make sure you have the replacement module available before removing the defective module. Once you remove the fan module, you have approximately 15 minutes to install the new module. Operating the disk array without a fan module for more than 15 minutes may cause a thermal shutdown. 258 Controller Enclosure Troubleshooting