Panasonic WJND300A WJND300A User Guide - Page 34
LIVE VIDEO, Manual REC Operation, EVENT REC, MANUAL, CONTINUE, Notes, ADM Activity Detection Mode
View all Panasonic WJND300A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
I LIVE VIDEO Set the transmission rate of live images from cameras. The following are available for the transmission rate. OFF/0.1 ips/0.2 ips/0.3 ips/0.5 ips/1 ips/2 ips/3 ips/ 5 ips/10 ips/15 ips I Manual REC Operation Perform the recording rate for manual recording. The following are available for "Recording Rate". OFF/0.1 ips/0.2 ips/0.3 ips/0.5 ips/1 ips/2 ips/3 ips/ 5 ips/10 ips/15 ips I EVENT REC Set the recording rate, recording duration and the event action mode when an event (site alarm, terminal alarm, command alarm) occurs. The following are available for "Recording Rate". OFF/0.1 ips/0.2 ips/0.3 ips/0.5 ips/1 ips/2 ips/3 ips/ 5 ips/10 ips/15 ips The following are available for "Time" (recording duration). 1 s - 10 s (in 1 second intervals)/20 s/30 s/1 min 10 min (in 1 minute intervals)/20 min/30 min/40 min/ 50 min/ 60 min MANUAL: Recording will be performed while alarm sig- nals (site alarm, terminal alarm, command alarm) are being supplied. CONTINUE: Recording will not stop until the [ALARM RESET] button is clicked. Notes: • When "MANUAL" is selected for "Time" (recording duration), recording will be performed for at least 8 seconds at an event occurrence as long as the alarm is not canceled. • Pre-event recording will not be performed. I EVENT SETUP Perform the settings for the alarm output duration and the buzzer sound duration at an event (site alarm, terminal alarm or command alarm) occurrence. The following are available for alarm output duration. When OFF is selected, the alarm output will not be supplied. (s: second, min: minute) 1 s - 30 s (in 1 second intervals)/40 s/50 s/1 min/2 min/ 3 min/4 min/5 min EXT: The alarm output will continue until the [ALARM RESET] button is clicked. OFF: No alarm output is supplied. REC: The alarm output will be supplied during recording is being performed. The following are available for "Buzzer" (buzzer sound duration). When OFF is selected, a buzzer will not sound. 1 s - 30 s (in 1 second intervals)/40 s/50 s/1 min/2 min/ 3 min/4 min/5 min EXT: The buzzer will continue until the [ALARM RESET] button is clicked. OFF: The buzzer will not sound. REC: The buzzer will sound only during recording is being performed. I Power ON Manual REC Select ON or OFF to determine whether or not to start recording when the power is turned on by the connected external timer (or the switch). ON: Manual recording will start automatically after com- pleting the system check. OFF: Manual recording will not start automatically after completing the system check. The following are available for the event action mode. Refer to the Operating Instructions (PDF) for further information about each event action mode. ADM (Activity Detection Mode): Performs recording, preset function and writing an event log at an event occurrence. Other event actions will not be performed. ALM (Alarm Mode): Performs recording, preset function and writing an event log, supplying the alarm output and sounding the buzzer according to the settings for "Event Setup". OFF: Performs only recording of the event log. Other event actions will not be performed. 34