Dell PowerEdge M520 Dell Converged Enhanced Ethernet Command Reference
Dell PowerEdge M520 Manual
View all Dell PowerEdge M520 manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerEdge M520 manual content summary:
- Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 1
53-1002115-01 07 December 2010 Dell Converged Enhanced Ethernet Command Reference - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 2
the DELL logo, Inspiron, Dell Precision, Dimension, OptiPlex, Latitude, PowerEdge, PowerVault, PowerApp, and Dell OpenManage are trademarks of Dell Inc.; Intel, Pentium, and Celeron are registered trademarks of Intel Corporation in the U.S. and other countries; Microsoft, Windows, Windows Server, MS - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 3
chapter xiii How this document is organized xiii Supported hardware and software xiv Document conventions xiv Text Accessing the Dell CEE Switch 1 CLI command modes 1 L2 ACL commands 3 Internal and external 10 Gbps Ethernet interfaces syntax 3 Chapter 2 Configuration Management Commands - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 4
tech-support 40 show users 41 show version 42 terminal length 43 terminal monitor 44 write erase 45 write memory 46 VLAN Commands interface vlan 47 show interface 48 show vlan 49 show vlan classifier 50 switchport 51 switchport access 52 switchport converged 53 iv Dell - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 5
interface 66 show ip interface 68 shutdown 70 speed 71 track 72 track interface 73 IP Configuration Commands arp 75 arp-ageing-timeout 76 clear arp-cache 77 clear ip fib 78 clear ip forwarding 91 show ip interface 92 Dell Converged Enhanced Ethernet Command Reference v 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 6
Aggregation Control Protocol Commands channel-group 121 clear lacp 123 clear lacp counters 124 debug lacp 125 lacp system-priority 127 lacp timeout 128 vi Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 7
channel 132 Layer 2 System Commands mac-address-table 133 show mac-address-table 135 FCoE Configuration Commands fcoe-map 137 fcoeport 138 fcoe-vlan 139 show fcoe-map 140 Layer 2 ACL interval 163 forward-delay 164 Dell Converged Enhanced Ethernet Command Reference vii 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 8
group 199 clear ip igmp groups 201 debug ip igmp all 202 ip igmp last-member-query-interval 203 ip igmp query-interval 204 viii Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 9
monitor 229 RMON Commands rmon alarm 231 rmon collection history 233 rmon collection stats 234 rmon event 235 show rmon 236 show rmon history 238 Dell Converged Enhanced Ethernet Command Reference ix 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 10
quiet-period 272 dot1x reauthenticate interface 273 dot1x reauthentication 274 dot1x reauthMax 275 dot1x timeout re-authperiod 276 dot1x timeout server-timeout 277 dot1x timeout supp-timeout 278 dot1x timeout tx-period 279 x Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 11
show dot1x 280 show dot1x all 281 show dot1x diagnostics interface 283 show dot1x interface 284 show dot1x session-info interface 285 show dot1x statistics interface 286 Dell Converged Enhanced Ethernet Command Reference xi 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 12
xii Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 13
configure interfaces. • Chapter 5, "IP Configuration Commands"describes the commands for configuring IP. • Chapter 6, "Link Layer Discovery Protocol Commands" describes the commands that support the commands used to configure and maintain IGMP snooping. Dell Converged Enhanced Ethernet Command - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 14
port authentication configuration commands. Supported hardware and software The following hardware platform is supported in this release: • Dell M8428-k Within this manual, any appearance of the term "Dell FCoE hardware" is referring to: • Dell M8428-k • Dell FCOE10-24 port blade • Dell Converged - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 15
. Notes, cautions, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards. NOTE of their respective companies and corporations. Dell Converged Enhanced Ethernet Command Reference xv 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 16
Red Hat, Red Hat Network, Maximum RPM, Linux Undercover Getting technical help Dell is committed to ensuring that your investment in our products remains cost-effective. If you need assistance, or find errors in the manuals, contact Dell Technical Support. Contacting Dell For customers in the - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 17
disabled and must be enabled. Refer to the Fibre Channel over Ethernet Administrator's Guide for information regarding feature configuration and management procedures. Following is an example of logging in to a switch supporting FCoE and CEE. telnet 10.32.152.21 switch login: userid Password:xxxxxx - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 18
a Telnet session. From the global configuration mode, specify a feature by entering one of the following feature names: • cee-map • fcoe-map • mac access-list • monitor session Access and configure CEE, FCoE, Port Mirroring, and ACL features. 2 Dell Converged Enhanced Ethernet Command Reference - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 19
IDs and different encapsulations. • Configure multiple access-lists or rules and store them in a configuration. • After you apply protocols, TCP or UDP port numbers, type of service and to provide Reflective access-lists and Time- Dell Converged Enhanced Ethernet Command Reference 3 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 20
1 Internal and external 10 Gbps Ethernet interfaces syntax 4 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 21
server/path] SCP Copies to URL scp:// [username [:password]@server/path] running-config Copies to the current running configuration. startup--config Copies to the current startup configuration write erase, copy running-config Dell Converged Enhanced Ethernet Command Reference 5 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 22
file to a network server or a file URL. Usage Guidelines The following guidelines apply when using this command: • An error displays if there is no startup configuration file, for example: switch #copy startup-config file2 % Error: No Startup-config. • Use the write memory command to add - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 23
switch using the following format: [flash://]filename. Defaults There is no default configuration for this command. Command Privileged EXEC mode Modes Description Use this command to ?(y/n):y See Also copy startup-config Dell Converged Enhanced Ethernet Command Reference 7 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 24
Feb 4 07:10:30 2009 Wed Feb 4 07:12:33 2009 Wed Feb 4 10:18:15 2009 startup_rmon_config rmon_config rmon_configuration starup-config See Also delete 8 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 25
to the EXEC mode. Synopsis disable Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to #disable switch> See Also enable, end, exit Dell Converged Enhanced Ethernet Command Reference 9 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 26
default configurations for this command. Command All configuration modes Modes Description Use this command to save time when you are configuring the switch in any configuration mode starup-config See Also none 10 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 27
Privilege EXEC mode. Synopsis enable Operands none Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to EXEC mode: switch> enable switch# See Also disable Dell Converged Enhanced Ethernet Command Reference 11 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 28
all configuration modes. Synopsis end Operands none Defaults There are no default configurations for this command. Command All configuration Examples To return to the Privileged EXEC mode from interface configuration mode: switch(config)#interface intengigabitethernet 0/0 switch(conf-if-te - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 29
Synopsis erase flash Operands none Defaults There are no default configurations for this command. Command Configuration mode Modes Description Use this command to erase the files erase?(y/n):y switch# See Also dir, delete Dell Converged Enhanced Ethernet Command Reference 13 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 30
The default is 10 minutes. Command Console and VTY (line) configuration mode Modes Description Use this command to set the interval; the 0 (zero) causes the Telnet session to wait indefinitely. Examples To configure the wait interval for the console session: switch(config)#line console 0 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 31
previous mode. Synopsis exit Operands none Defaults There are no default configurations for this command. Command All command modes Modes Description Use this Examples To exit the Interface configuration mode, and return to the Configuration mode: switch(config)#interface intengigabitethernet - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 32
fos command command Specifies the Fabric OS command. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to portstatsshow slotpoweroff slotpoweron slotshow 16 Dell Converged Enhanced Ethernet Command Reference - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 33
applies to the listed commands. The fcoelogincfg, fcoelogingroup, and fcoelogincfg commands are not supported from cmsh shell. See the Fabric OS Command Reference for additional information on :00:05:1e:76:42:00 See Also none Dell Converged Enhanced Ethernet Command Reference 17 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 34
configurations for this command. Command Global configuration mode Modes Description Use this command to configure the Line configuration mode, which allows you to configure Guidelines Examples To configure the wait interval for the console session: switch>enable switch#configure terminal switch( - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 35
wait interval for the telnet session to time out after 2 minutes, 30 seconds if there is no response from the user: switch#configure terminal switch(config)#line vty 23 31 switch(conf-line)#exec-timeout 2 30 See Also show line Dell Converged Enhanced Ethernet Command Reference 19 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 36
-mode enable Operands none Description In the Blade Center Chassis environment, the Management Module (AMM) controls the operation of the switch by configuring and initializing it. Protect mode of operation is a special mode which needs to be supported by both the switch and the AMM. Protect - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 37
current working directory. Synopsis pwd Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command directory: switch#pwd flash: See Also none Dell Converged Enhanced Ethernet Command Reference 21 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 38
to change. Specifies the new name of the file. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to rename Feb 4 13:16:00 2009 file2 See Also none 22 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 39
. Command Privileged EXEC Mode Modes User Guidelines The scripting support only supports textual configuration files. It does not handle any scripting languages, such as Tcl, Expect, and so on. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 23 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 40
Use this command to display accounting logs. Defaults There are no default configurations for this command. Command Privileged EXEC Mode Modes User Guidelines There are Frisco-34, config; rmon event 15 See Also none 24 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 41
switch hardware clock. Synopsis show calendar Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to Tue Feb 14 2009 See Also none Dell Converged Enhanced Ethernet Command Reference 25 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 42
from the system clock. Synopsis show clock Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to display 2009 See Also show calendar 26 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 43
the switch. Synopsis show environment Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command 3 Ok 47 116 4 Ok 32 89 See Also none Dell Converged Enhanced Ethernet Command Reference 27 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 44
the file whose contents are to be displayed. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to -tree mstp instance 1 vlan 100 ! See Also dir 28 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 45
24 24 switch#show line 0 Status Type Idle console 0 * Active vty 0 Timeout(m/s) 10:0 10:0 Length 24 24 See Also line vty, line console, exec-timeout Dell Converged Enhanced Ethernet Command Reference 29 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 46
the switch. Synopsis show logging Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command Port-channel 10 is link down See Also none 30 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 47
switch. Synopsis show media Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this truncated) See Also show media interface, show media linecard Dell Converged Enhanced Ethernet Command Reference 31 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 48
for a specific interface. show media interface {{in | ex}tengigabitethernet slot/port} Operands extengigabitethernet Specifies a valid external 10 Gbps Ethernet interface. slot Specifies a valid slot number. port Specifies a valid port number. Defaults There are no default configurations for - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 49
the interfaces of a specific line card. show media linecard number number Linecard number. Defaults There are no default configurations for this command. (uWatts) (output truncated) See Also show media interface, show media Dell Converged Enhanced Ethernet Command Reference 33 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 50
a summary of CPU usage by all processes. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to display 0.00 S 14:18:35 Feb 19, 2009 See Also none 34 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 51
memory [summary] Operands summary Shows a summary of memory usage by all processes. Defaults There are no default configurations - 3 events/0 0.00 0 - - 4 khelper 0.00 0 - - 5 kthread 0.00 0 - - See Also none Dell Converged Enhanced Ethernet Command Reference 35 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 52
-mode status Operands none Description Use this command to display the current status of protect mode. Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also none 36 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 53
mode Modes Description Use this command to display the contents of the configuration file currently running on the system. The show running-config command displays InTenGigabitEthernet 0/4 shutdown ! See Also show startup-config Dell Converged Enhanced Ethernet Command Reference 37 53-1002115- - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 54
in the startup configuration file, for example switch#show startup-config % No Startup-config • Use the write memory command to add entries to the startup configuration file. • 0/3 shutdown See Also write memory, write erase 38 Dell Converged Enhanced Ethernet Command Reference - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 55
information. Synopsis show system Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this is Ok Fan 3 is Ok See Also show version, show environment Dell Converged Enhanced Ethernet Command Reference 39 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 56
support show tech-support Displays output for troubleshooting. Synopsis show tech-support Operands none Defaults There are no default configurations Switch Model Name: Dell M8428-k Control Processor: Freescale Semiconductor 8548E with 1016 MB of memory 4MB of boot flash memory. 8 FC Port(s) - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 57
into the switch. Synopsis show users Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to of all users logged in. See Also show line Dell Converged Enhanced Ethernet Command Reference 41 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 58
version Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode name: v6.1.2 Switch Model Name: Dell M8428-k Control Processor: Freescale Semiconductor 8548E with 1016 MB of memory 4MB of boot flash memory. 8 FC Port(s) 24 Ten GigabitEthernet - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 59
screens of output. Guidelines Examples To set the number of lines to display on the screen to 30: switch#terminal length 30 See Also none Dell Converged Enhanced Ethernet Command Reference 43 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 60
a terminal: switch#terminal monitor To disable the display of the RASlog and the debug outputs on a terminal: switch#terminal no monitor See Also none 44 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 61
Description Use this command to remove a startup configuration. Usage There are no usage guidelines for this command. Guidelines Examples To clear a startup configuration: switch#write erase See Also write memory write erase 2 Dell Converged Enhanced Ethernet Command Reference 45 53-1002115 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 62
. Usage There are no usage guidelines for this command. Guidelines Examples To write configuration data to a file: switch#write memory Overwrite the startup config file (y/n): y Building configuration... See Also write erase 46 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 63
VLAN 1 is predefined on the switch. Command Modes Description Global configuration mode Use this command to configure a VLAN interface. Use the no interface vlan vlan_id command Also interface switchport, fcf forward, shutdown Dell Converged Enhanced Ethernet Command Reference 47 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 64
switchport Specifies the Layer 2 interface. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command access : enable : all : 5 : 5 : - See Also show interface vlan 48 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 65
Synopsis Operands Displays information about a specific VLAN interface. show vlan {vlan_id interfaces. Defaults There are no default configurations for this command. Command Privileged EXEC mode 1(t) Po 63(t) See Also none Dell Converged Enhanced Ethernet Command Reference 49 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 66
If a group ID is Guidelines specified, a specific configured VLAN classifier group is shown. Examples To display the VLAN classifier for group 1: switch#show vlan classifier group 1 vlan classifier group 1 rule 1 See Also none 50 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 67
default VLAN 1 and the interface is set to access mode. Command Interface configuration mode Modes Description Use this command to set the switching characteristics of the Layer mode, switchport access, switchport trunk Dell Converged Enhanced Ethernet Command Reference 51 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 68
Layer 2 interfaces are in access mode and belong to the VLAN ID 1. Command Interface configuration mode Modes Description Use this command to set the Layer 2 interface as access. In switchport, switchport mode, switchport trunk 52 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 69
2-3583. Defaults The default native VLAN for a converged interface is 1. Command Interface configuration mode Modes Description Use this command to add or remove tagged VLANs on a Layer , switchport mode, switchport trunk Dell Converged Enhanced Ethernet Command Reference 53 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 70
interface as converged. Defaults There are no defaults for this command. Command Interface configuration mode Modes Description Use this command to set the mode of the Layer 2 interface interface switchport, switchport trunk 54 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 71
of valid values is 2-3583. Defaults There are no default configurations for this command. Command Interface configuration mode Modes Description Use this command to add or remove switchport, switchport mode, switchport trunk Dell Converged Enhanced Ethernet Command Reference 55 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 72
of valid values is 1-3583. Defaults There are no default configurations for this command. Command Interface configuration mode Modes Description Use this command to activate a VLAN activate group 1 vlan 5 See Also none 56 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 73
of valid values is 1-256. Defaults There are no default configurations for this command. Command Global configuration mode Modes Description Use this command to add and delete vlan classifier group 1 add rule 1 See Also none Dell Converged Enhanced Ethernet Command Reference 57 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 74
address-based VLAN classifier rule used to map to a specific VLAN. vlan Specifies the vlan. Valid values configurations for this command. Command Global configuration mode Modes Description Use this command to configure Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 75
See Also show vlan interface vlan classifier rule 3 Dell Converged Enhanced Ethernet Command Reference 59 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 76
3 vlan classifier rule 60 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 77
on one or on all interfaces. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes User Guidelines The clear protocol daemon stats like LLDP, LACP, MSTP, and so on. For the Dell M8428-k switch, the slot number is always 0 (zero). Example To clear - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 78
4 clear counters See Also show interfaces 62 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 79
of characters is 64. Defaults There are no default configurations for this command. Command Interface configuration mode Modes Description Use this command to specify a (conf-if-te-0/1)#description converged_101 See Also none Dell Converged Enhanced Ethernet Command Reference 63 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 80
Description Use this command to create or enter the interface configuration mode to configure an interface. Usage There are no usage guidelines for this command. Guidelines Examples none See Also show interface, interface vlan 64 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 81
MTU size is 1522-9208 bytes. Defaults By default, all 10 Gbps Ethernet interfaces use a default MTU of 2500 bytes. Command Interface configuration mode Modes Description Use this command to specify the MTU on the interface. Usage Creating MTUs under VLAN interfaces is not valid. Guidelines - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 82
this command to display the detailed interface configuration and capabilities of all interfaces or for a specific interface. Usage There are no usage 0 Over 1518-byte pkts(Jumbo): 0 Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0 66 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 83
Interface name Switchport mode Ingress filter Acceptable frame types Default Vlan Active Vlans Inactive Vlans : ExTenGigabitEthernet 0/20 : trunk : enable : vlan-tagged only : 0 : 1 : - show ip interface Dell Converged Enhanced Ethernet Command Reference 67 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 84
| vlan vlan_id brief} brief Specifies to display a brief summary of the IP status and configuration. port-channel number Specifies to display the port-channel number. The range of valid values up down up up down up up down down 68 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 85
administratively down administratively down down up up up down down up up down up down up down up up up up up down down down Dell Converged Enhanced Ethernet Command Reference 69 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 86
no shutdown Operands none Defaults The interface is disabled. Command Interface configuration mode Modes Description Use this command to disable an interface. Usage See Also interface, show ip interface, show interface 70 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 87
interface. Defaults The default setting for this command is auto. Command Interface configuration mode. Modes User Guidelines The speed command is available only for intengigabitethernet -if-int-0/1)#speed 10000 See Also none Dell Converged Enhanced Ethernet Command Reference 71 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 88
track enable no track enable Operands none Description Use this command to enable tracking. Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines Use the no track version to disable this command. Example none See Also none 72 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 89
values is 1-63. Description Use this command to enable tracking on an interface. Defaults There are no default configurations for this command. Command Interface configuration mode Modes User Guidelines Use the no track interface version to disable this command. Example none See Also none - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 90
4 track interface 74 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 91
Commands Chapter 5 arp Synopsis Operands Configures a static ARP connection. arp ip-address hardware to a local data link address. Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines There are no usage guidelines for this - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 92
ageing-timeout minutes Number of minutes until the timeout occurs. Description Use this command to configure the ARP timeout. Defaults Default value is 240 minutes (four hours.) Command Global configuration mode Modes User Guidelines Use no arp-ageing-timeout to disable this function. Example - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 93
the ARP cache for the specified interface only. interface-type Network interface type (external TenGigabitEthernet interface, null, port-channel, or ARP statistics cache on the host. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 94
slot-number} slot slot-number Clears the FIB and hardware for the blade slot number. The only valid value is 0. Description Use this command to clear the FIB and hardware. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 95
or all interfaces on the switch. clear ip route {network [mask] | *} network mask * Network or subnet address to clear. Mask for the route configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also none Dell - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 96
statistics. Synopsis clear ip traffic Operands none Description Use this command to clear the IP traffic statistics. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also none - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 97
the ARP traffic for the specified interface only. interface-type Network interface type (external TenGigabitEthernet interface, null, port-channel, or ARP traffic, for all interfaces or a specific interface. Defaults There are no default configurations for this command. Command EXEC mode Modes - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 98
IP traffic for the specified interface only. interface-type Network interface type (external TenGigabitEthernet interface, null, port-channel per interface, or on a multicast group. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 99
supported. Dotted-decimal is not supported. Specifies that the configured address is a secondary IP address. If this keyword is omitted, the configured secondary address cannot be configured in the absence of a primary IP. Example none See Also none Dell Converged Enhanced Ethernet Command - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 100
IP MTU size is 1500 bytes. The default link MTU is 2500 bytes. Command VLAN interface configuration mode Modes User Guidelines Use the command no ip mtu to disable the MTU. The valid is 2500 bytes. Example none See Also none 84 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 101
disabled. Command Privileged EXEC mode Modes User Guidelines Use no ip proxy-arp to disable proxy ARP. Example none See Also none ip proxy-arp 5 Dell Converged Enhanced Ethernet Command Reference 85 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 102
ip route Synopsis Operands Configures a static IP route supported. IP address of the next hop that can be used to reach that network. interface interface-type Network to configure static IP routes. Defaults There are no default configurations for this command. Command Global configuration mode. - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 103
violations to CPU. Description Use this command to trap IP fragmentations or TTL violations to the CPU. Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines Use no ip trap-to-cpu to disable the trap. Example none See Also none - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 104
the ARP cache for the specified interface only. interface-type Network interface type (external TenGigabitEthernet interface, null, port-channel, the contents of the ARP cache. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 105
interface-type interface-number Network interface type (external TenGigabitEthernet interface, null, port-channel, or VLAN). Layer-2 or layer-3 Interface number. Description Use this command to display interface information. Defaults There are no default configurations for this command. Command - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 106
chip-number] slot slot-number Displays the FIB and hardware for the blade slot number. The only valid value is 0. number chip-number Displays command to display the FIB information. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 107
forwarding. Synopsis show ip forwarding Operands none Description Use this command to display the status of IP forwarding. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also show - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 108
particular interface if preceded by the interface. interface-type Network interface type (external TenGigabitEthernet interface, null, port-channel, to display IP interface information. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 109
information. Defaults There are no default configurations for this command. Command EXEC static route Gateway of last resort is 10.32.144.1 to network 0.0.0.0 10.0.0.0/8 is variably subnetted, 2 subnets, 2 masks S summary Dell Converged Enhanced Ethernet Command Reference 93 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 110
current IP routing table. Defaults There are no default configurations for this command. Command EXEC mode Modes User Guidelines There Networks Subnets connected 0 1 static 1 1 internal 1 Total 2 2 Overhead 64 128 192 See Also show ip route Memory (bytes) 160 320 1180 1660 94 Dell - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 111
-app-tlv Operands none Defaults Advertise is disabled. Command Protocol LLDP configuration mode Modes Description Use this command to advertise application TLVs to ensure dot1-tlv, advertise dot3-tlv, advertise optional-tlv Dell Converged Enhanced Ethernet Command Reference 95 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 112
-fcoe-logical-link-tlv Operands none Defaults Advertise is disabled. Command Protocol LLDP configuration mode Modes Description Use this command to advertise to any attached device the FCoE app-tlv, advertise dcbx fcoe-app-tlv 96 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 113
dcbx-tlv Operands none Defaults Advertise is enabled. Command Protocol LLDP configuration mode Modes Description Advertises to any attached device mandatory Data Center Bridging , advertise dot3-tlv, advertise optional-tlv Dell Converged Enhanced Ethernet Command Reference 97 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 114
-tlv no advertise dot1-tlv Operands none Defaults Advertise is disabled. Command Protocol LLDP configuration mode Modes Description Use this command to advertise to any attached device IEEE 802.1 organizationally specific Type, Length, Value (TLV). Use the no advertise dot1-tlv command to return - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 115
-tlv no advertise dot3-tlv Operands none Defaults Advertise is disabled. Command Protocol LLDP configuration mode Modes Description Use this command to advertise to any attached device IEEE 802.3 organizationally specific Type, Length, Value (TLV). Use the no advertise dot3-tlv command to return - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 116
Specifies the name of the system. Defaults Advertise is disabled. Command Protocol LLDP configuration mode Modes Description Use this command to display the following optional TLVs. Use this command. Guidelines Examples none 100 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 117
number. port Specifies a valid port number. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to lldp neighbors See Also show lldp neighbors Dell Converged Enhanced Ethernet Command Reference 101 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 118
slot number. port Specifies a valid port number. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to statistics See Also show lldp statistics 102 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 119
Ethernet interface 0/1: switch#debug lldp packet interface intengigabitethernet 0/1 both switch#show debug lldp LLDP debugging status: Interface te0/1 : Transmit Receive See Also show debug lldp Dell Converged Enhanced Ethernet Command Reference 103 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 120
LLDP protocol. Defaults There are no default configurations for this command. Command Protocol LLDP configuration mode Modes Description Use this command to specify LLDP: switch(conf-lldp)#description Dell-LLDP See Also none 104 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 121
are no usage guidelines for this command. Guidelines Examples To set the time interval to 10 seconds between the transmissions: switch#configure terminal switch (config) #protocol lldp switch(conf-lldp)#hello 10 See Also none Dell Converged Enhanced Ethernet Command Reference 105 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 122
released prior to the CEE DCBX release. Defaults The default is auto. Command Interface configuration mode Modes Description Use this command to specify which version of the DCBX protocol to dcbx-version cee See Also none 106 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 123
By default, LLDP is enabled at both the global and interface levels. Command Interface configuration mode Modes Description Use this command to disable LLDP on the interface. Use the conf-if-te-0/1)#lldp disable See Also none Dell Converged Enhanced Ethernet Command Reference 107 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 124
range of valid values is 0 to 15. Defaults The default value is 8. Command Interface configuration mode Modes Description Use this command to set the priorities on which FCoE traffic will be -bits 15 See Also protocol lldp 108 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 125
in the profile, the default values are used. Command Interface configuration mode Modes Description Use this command to apply a Link Layer this command is not present, the parameters defined in the global LLDP configuration are used. Examples To apply an LLDP profile on an interface: switch - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 126
only the receive mode. Defaults Both transmit and receive modes are enabled. Command Protocol LLDP configuration mode Modes Description Use this command to set the LLDP mode on the switch. Use )#mode tx See Also show lldp 110 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 127
values is 1-10. Defaults The default multiplier value is 4. Command Protocol LLDP configuration mode Modes Description Use this command to set the number of consecutive misses of switch(conf-lldp)#multiplier 2 See Also hello Dell Converged Enhanced Ethernet Command Reference 111 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 128
apply an LLDP profile on an interface using the lldp profile command, it overrides the global configuration. If a profile is not present, then the default global profile is used until you profile test See Also lldp profile 112 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 129
no protocol lldp command to return to the default setting. Usage There are no usage guidelines for this command. Guidelines Examples To clear all LLDP configurations: switch(config)#no protocol lldp See Also none Dell Converged Enhanced Ethernet Command Reference 113 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 130
the switch. Synopsis show debug lldp Operands none Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to display /0 : Transmit Receive Detail See Also none 114 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 131
slot number. port Specifies a valid port number. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to display the FCoE Priority Bits: 0x8 See Also none Dell Converged Enhanced Ethernet Command Reference 115 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 132
the specified interface. Defaults There are no default configurations for this command. Command EXEC mode Modes Description display detailed LLDP neighbor information on a specific interface: switch#show lldp neighbors interface 116 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 133
Spanning Tree Protocol Remote VLANs Configured: VLAN ID: 1 VLAN Name: default AutoNego Support: Supported Not Enabled AutoNego Capability: 0 OperVersion: 0 MaxVersion: 0 EN: 1 Will: 0 Err: 0 Logic Link Status: Up switch# none Dell Converged Enhanced Ethernet Command Reference 117 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 134
number. port Specifies a valid port number. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to 554 TLVs discarded: 0 TLVs unrecognized: 0 See Also none 118 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 135
default configurations for this command. Command Protocol LLDP mode. Modes Description Use this command to set the global system description specific to LLDP global system description specific to LLDP: switch(conf-lldp)#system-description Dell See Also system-name Dell Converged Enhanced - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 136
of32 characters. Defaults By default, the host name from the switch is used. Command Protocol LLDP configuration mode Modes Description Use this command to set the global system name specific to LLDP. Usage There are no usage guidelines for this command. Guidelines Examples To specify a system - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 137
. Specifies the type of LAG. Specifies the 802.3ad standard-based LAG. Specifies the Dell proprietary hardware-based trunking. Defaults By default, the type is set to standard. Command Interface configuration mode Modes Description Use this command to add an interface to a port-channel specified - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 138
7 channel-group See Also switch(conf-if)#channel-group 4 mode active interface port-channel 122 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 139
per specified channel-group. Usage There are no default configurations for this command. Guidelines Examples To clear the LACP counters for a specific port-channel: switch#clear lacp 10 counters See Also show lacp counters Dell Converged Enhanced Ethernet Command Reference 123 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 140
clear lacp counters Operands none Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description LACP counters for all port-channels. Usage There are no default configurations for this command. Guidelines Examples To clear the counters for all - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 141
interface debugging. event Turns on event debugging. nsm Turns on Network Services Module (NSM) debugging. pdu Turns on PDU debugging. rx all display debug outputs on a specific cmsh session, use the terminal monitor command. Guidelines Dell Converged Enhanced Ethernet Command Reference - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 142
all switch#debug lacp pdu rx all switch#show debug lacp LACP rx debugging is on LACP tx debugging is on show debug lacp 126 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 143
guidelines for this command. Guidelines Examples To set the LACP system-priority to 68: switch(config)#lacp system-priority 68 To clear the configured LACP system-priority: switch(config)#no lacp system-priority See Also none Dell Converged Enhanced Ethernet Command Reference 127 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 144
a long timeout value. Specifies a short timeout value. Defaults By default, the short timeout value is 3 seconds for Dell trunks. For standard trunks, the long timeout value is 90 seconds. Command Interface configuration mode Modes Description Use this command to set the short timeout value for - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 145
number, then the port-channel is declared operationally DOWN even though it has operationally UP members. Defaults The default number of links is 1. Command Interface configuration mode Modes User Guidelines Use no minimum-links to disable this command. Example none See Also none - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 146
configurations for this command. Command EXEC mode Modes Description Use this command to display the LACP packet counters on all interfaces that belong to a port-channel or a specific 0 0 0 0 0 0 0 See Also clear lacp counters 130 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 147
information. Synopsis show lacp sys-id Operands none Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to display the -k,00-05-1e-76-1a-a6 See Also none Dell Converged Enhanced Ethernet Command Reference 131 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 148
Note LAG interfaces are called port-channels. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Displays the LAGs present : 0 % Link: Te 0/2 (67239938) sync: 0 See Also none 132 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 149
is 1-3583. Defaults The default aging time is 300 seconds. Command Global configuration mode Modes Description Use this command to set the aging time or to add the switch only supports independent VLAN learning (IVL). Guidelines Dell Converged Enhanced Ethernet Command Reference 133 53-1002115- - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 150
intengigabitethernet 0/1 vlan 100 To set the aging time to 10 minutes: switch(config)#mac-address-table aging-time 600 show mac address-table static 134 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 151
table static and dynamic entry or the MAC address table static and dynamic entries for a specific interface or VLAN. show mac-address-table [address mac-addr | aging-time | count is 1-3583. No static addresses are configured. Dell Converged Enhanced Ethernet Command Reference 135 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 152
3333 Static Inactive Te 0/1 Total MAC addresses : 1 To display the aging time for a specific MAC address table: switch#show mac-address-table aging-time MAC Aging-time : 300 seconds -table linecard, show mac address-table count 136 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 153
configuration mode. Synopsis fcoe-map default no fcoe-map Operands default The CEE map name. Defaults The only map name available is "default." Command Global configuration Defaults There are no default configurations for this command. Command Global configuration mode Modes User Guidelines - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 154
default configurations for this command. Command Interface configuration mode Modes User Guidelines If the interface is configured as fcoeport, the fcoeport configuration will precedence over the switchport mode. If the switchport mode is configured as access or trunk it will be ignored. Example - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 155
. Defaults There are no default configurations for this command. Command Feature configuration mode Modes Description Use this command to configure an FCoE VLAN to the FCoE You must first enter FCoE map mode, then configure the VLAN. switch(config)#fcoe-map default switch(conf-fcoe-map)#fcoe-vlan 5 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 156
Synopsis show fcoe-map Operands none Description Use this command to display the current FCoE map information. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes User Guidelines There are no usage guidelines for this command. Example none See Also - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 157
or for a specific interface for MAC access list counters. Usage If the interface keyword is not specified, then ACL counters on all interfaces which have this ACL Guidelines applied are cleared. There are 255 ACL counters supported per port group. Example To clear counters for the configured MAC - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 158
configure rules to match and drop traffic based on the source and destination MAC addresses and the protocol type. You can also enable counters for a specific rule. There are 255 ACL counters supported from a MAC extended ACL: 142 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 159
deny (extended ACLs) 10 See Also switch(conf-macl-ext)#no deny 0022.3333.4444 0022.3333.5555 ipv4 mac-access-list extended, mac-access-list standard, permit Dell Converged Enhanced Ethernet Command Reference 143 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 160
MAC ACLs are configured. Command Feature Access Control List Configuration mode Modes Description Use this command to configure rules to match and to drop traffic based on the source MAC address. You can also enable counters for a specific rule. There are 255 ACL counters supported per port group - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 161
the ACL is already created, this command puts the switch in the extended MAC access-list configuration mode. Use the no mac access-list extended command to remove the access list. Extended See Also deny, permit, show access-lists Dell Converged Enhanced Ethernet Command Reference 145 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 162
If ACL is already created, this command puts the switch in the standard MAC access-list configuration mode. Use the no mac access-list standard command to remove the access list. Standard ACLs Also deny, permit, show access-lists 146 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 163
2 or a VLAN interface. You create the MAC ACL by using the mac access-list global configuration command. Use the no mac access-group command to remove the MAC ACL from the interface. Usage -list extended, show access-lists Dell Converged Enhanced Ethernet Command Reference 147 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 164
configure rules to match and to permit traffic based on the source and destination MAC addresses, and the protocol type. You can also enable counters for a specific rule. There are 255 ACL counters supported .3333.5555 ipv4 count 148 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 165
permit (extended ACLs) 10 See Also To delete a filter rule in a MAC extended ACL: switch(conf-macl-ext)#no permit 0022.3333.4444 0022.3333.5555 ipv4 mac-access-list extended, mac-access-list standard, no seq Dell Converged Enhanced Ethernet Command Reference 149 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 166
Configuration mode Modes Description Use this command to configure rules to match and to permit traffic based on the source MAC address. You can also enable counters for a specific rule. There are 255 ACL counters supported seq 150 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 167
rules. The range of valid values is 1-65535. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to reassign ! See Also mac-access-list extended, seq Dell Converged Enhanced Ethernet Command Reference 151 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 168
to insert a rule anywhere in the MAC ACL; it configures rules to match and permits or drops traffic based on the source and destination MAC addresses, and the protocol type. You can also enable counters for a specific rule. There are 255 ACL counters supported per port group. Use the no seq value - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 169
0022.3333.4444 0022.3333.5555 ipv4 count To delete a rule from a MAC extended ACL: switch(conf-macl-ext)#no seq 100 deny, permit, resequence Dell Converged Enhanced Ethernet Command Reference 153 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 170
configure rules to match and permit or drop traffic based on source and destination MAC address and protocol type. You can also enable counters for a specific rule. There are 255 ACL counters supported deny, permit, resequence 154 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 171
number. The range of valid values is 1-3583. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to display the See Also show running-config, show statistics Dell Converged Enhanced Ethernet Command Reference 155 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 172
number. The range of valid values is 1-3583. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to display the Also show running-config, show mac access-group 156 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 173
switch(config)#protocol spanning-tree rstp switch(conf-rstp)#bridge-priority 8192 switch#configure terminal switch(config)#protocol spanning-tree mstp switch(conf-mstp)#bridge-priority 8192 see Also protocol spanning-tree Dell Converged Enhanced Ethernet Command Reference 157 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 174
is required on any switch in the network, then all switches in the network must be compatible, and therefore enabled using this command for interoperability with a Cisco switch. Examples To enable Cisco interoperability on a switch: switch#configure terminal switch(config)#protocol spanning-tree - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 175
valid slot number. Specifies a valid port number. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes Description Use this command to port-channel 23 See Also show spanning-tree Dell Converged Enhanced Ethernet Command Reference 159 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 176
-tree MSTP debugging status: Spanning-tree rx debugging is off Te 0/1 rx is on Spanning-tree tx debugging is off Te 0/1 tx is on 160 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 177
See Also show debug spanning-tree, show debug debug spanning-tree 11 Dell Converged Enhanced Ethernet Command Reference 161 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 178
Operands none Defaults There are no default configurations for this command. Command Protocol Spanning Tree remains in the disabled state unless the port is enabled manually. This command allows you to enable the interface from the Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 179
command. Guidelines Examples To set the timeout value to 10 seconds: switch(conf-rstp)#error-disable-timeout interval 10 See Also error-disable-timeout enable Dell Converged Enhanced Ethernet Command Reference 163 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 180
-delay, the following relationship should be kept: 2*(forward-delay - 1)>=max-age>=2*(hello-time + 1) Examples To configure the forward-delay time to 18 seconds: switch(conf-mstp)#forward-delay 18 See Also hello-time, max age 164 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 181
Tree mode Modes Description Use this command to configure the spanning-tree bridge hello time, which to the default settings. Usage Guidelines When configuring the hello-time, the max-age setting age>=2*(hello-time + 1) Examples To configure spanning-tree bridge hello time to 5 seconds: switch( - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 182
be created before mapping to instances. • VLAN instance mapping is removed from the configuration if the underlying VLANs are deleted. Examples To map a VLAN to an MTSP )#instance 1 priority 4096 See Also show spanning-tree 166 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 183
age seconds no max-age seconds Configures the Spanning tree Protocol interface maximum saves its configuration Bridge Protocol Data Unit (BPDU to the default configuration. Usage Guidelines When configuring the maximum age, + 1) Examples To configure the maximum-age to 10 seconds: switch(conf - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 184
The default is 20 hops. Command Protocol Spanning Tree MSTP mode Modes Description Use this command to configure the maximum number of hops for a BPDU in an MSTP region. This parameter is used by Also show spanning-tree mst 168 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 185
-channel path-cost custom To set the behavior for the path-cost to standard: switch(conf-mstp)#port-channel path-cost standard See Also none Dell Converged Enhanced Ethernet Command Reference 169 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 186
. Use the no protocol spanning-tree command to delete the context and all the configurations defined within the context or protocol for the interface. Usage Guidelines Consider enabling STP to stp See Also show spanning-tree 170 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 187
-name Assigns a name to an MSTP region. Defaults There are no default configurations for this command. Command Protocol Spanning Tree MSTP mode Modes Description Usage Guidelines Use See Also revision, show spanning-tree Dell Converged Enhanced Ethernet Command Reference 171 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 188
Spanning Tree Protocol (MSTP) configuration. revision number no revision number Modes Description Use this command to specify the configuration revision number. Use the no revision command command. Guidelines Examples To set the configuration revision to 1: switch(config)#protocol spanning- - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 189
CIST Root Forward Delay: 15; Hello Time: 2; Max Age: 20; Max-hops: 20 Configured Forward Delay: 15; Hello Time: 2; Max Age: 20; Max-hops: 20; Tx-HoldCount External Path Cost: 0; Internal Path Cost 0 Configured Path Cost: 2000 Dell Converged Enhanced Ethernet Command Reference 173 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 190
; EdgeDelay: 3 sec Configured Root guard: off; Operational : 0; Internal Path Cost 0 Configured Path Cost: 2000 Designated Port ; EdgeDelay: 3 sec Configured Root guard: off; Operational : 0; Internal Path Cost 0 Configured Path Cost: 2000 Designated Port ; EdgeDelay: 3 sec Configured Root guard: off; - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 191
. Synopsis show spanning-tree brief Operands none Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to Yes No See Also show spanning-tree interface Dell Converged Enhanced Ethernet Command Reference 175 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 192
number. Defaults There are no default configurations for this command. Command EXEC mode Disabled; State: Discarding Designated Path Cost: 0 Configured Path Cost: 2000 Designated Port Id: 0; Port : no; AdminEdge: no; EdgeDelay: 3 sec Configured Root guard: off; Operational Root guard: off - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 193
32768 Address 0005.1e76.1aa0 Priority 32768 Address 0005.1e76.1aa0 Priority 32768 Address 0005.1e76.1aa0 Configured Hello Time 2, Max Age 20, Forward Delay 15 Max Hops 20, Tx-HoldCount 6 CIST , show spanning-tree mst instance Dell Converged Enhanced Ethernet Command Reference 177 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 194
: 0; Vlans:1, 100 Port Te 0/0 enabled IfIndex: 67108864; Id: 8000; Role: Disabled; State: Discarding Designated External Path Cost: 0; Internal Path Cost 0 Configured Path Cost: 2000 Designated Port Id: 0; CIST Priority: 128 178 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 195
: 3 sec Configured Root guard: off Internal Path Cost 0 Configured Path Cost: 2000 : 3 sec Configured Root guard: off Internal Path Cost 0 Configured Path Cost: 2000 Designated : 3 sec Configured Root guard: off Internal Path Cost 0 Configured Path Cost: 2000 Designated sec Configured Root guard: off - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 196
11 show spanning-tree mst detail See Also Link-type: point-to-point Received BPDUs: 0; Sent BPDUs: 0 MSTI details show spanning-tree mst interface, show spanning-tree mst instance 180 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 197
which to display information on the MSPT instance. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to display -tree mst brief, show spanning-tree interface Dell Converged Enhanced Ethernet Command Reference 181 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 198
There are no default configurations for this command. Command EXEC mode Modes Description Use this command to display MSTP protocol specific information such as Common show spanning-tree brief, show spanning-tree mst brief 182 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 199
spanning-tree rstp switch(conf-rstp)#shutdown To enable STP globally: switch(config)#protocol spanning-tree rstp switch(conf-rstp)#no shutdown See Also none Dell Converged Enhanced Ethernet Command Reference 183 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 200
tree autoedge Operands none Defaults Auto detection is not enabled. Command Interface configuration mode Modes Description Use this command to automatically identify the edge port autoedge See Also protocol spanning-tree 184 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 201
this command to configure the path cost for spanning-tree calculations. Usage Lower path cost indicates a greater chance of becoming root. Guidelines Examples To set the port cost to 128: switch(conf-if-te-0/1)#spanning-tree cost 128 See Also show spanning-tree Dell Converged Enhanced Ethernet - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 202
. Defaults Edge port is disabled. Command Interface configuration mode Modes Description Use this command to enable the end stations cannot create bridging loops in the network, edge ports directly transition to the forwarding state Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 203
spanning-tree guard root Operands none Defaults Guard root is disabled. Command Interface configuration mode Modes Description Use this command to enable the guard root on the guard root See Also spanning-tree cost Dell Converged Enhanced Ethernet Command Reference 187 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 204
sent by the root switch configuration messages. The range of valid values 1-10. Defaults The default is 2 seconds. Command Interface configuration mode Modes Description Use this forward-delay, max-age, show spanning-tree 188 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 205
mode Modes Description Use this command to set restrictions for a port on a particular MSTP instance. Usage Use this command for MSTP-specific configurations. Guidelines Examples To set restrictions for the port of MSTP instance 1 with the cost of 40000: switch(conf-if-te-0/1)#spanning-tree - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 206
. Disables rapid transition. Defaults The default is point-to-point. Command Interface configuration mode Modes Description Use this command to specify a link type for the Spanning link-type shared, no spanning-tree link-type 190 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 207
the port against the reception of BPDUs. Defaults Port Fast is disabled. Command Interface configuration mode Modes Description Use this command to enable the Port Fast feature. This command -guard, spanning-tree autoedge Dell Converged Enhanced Ethernet Command Reference 191 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 208
increments of 16. Defaults The default value is 128. Command Interface configuration mode Modes Description Use this command to change an interface's spanning are no usage guidelines for this command. Guidelines Examples To configure the port priority to 16: switch(conf-if-te-0/1)#spanning-tree - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 209
The restricted role is disabled. Command Interface configuration mode Modes Description Use this command to configure the port from becoming a root port. are no usage guidelines for this command. Guidelines Examples To configure the port from becoming a root port: switch(conf-if-te-0/1)#spanning- - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 210
Operands none Defaults The restricted TCN is disabled. Command Interface configuration mode Modes Description Use this command to restrict the topology . Guidelines Examples To restrict the TCN on a specific interface: switch(conf-if-te-0/1)#spanning-tree restricted-tcn See Also show - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 211
interface or VLAN. Once all of the interface ports have been configured for a VLAN, you can enable spanning tree protocol (STP) To disable spanning tree on a specific interface: switch(config)#interface intengigabitethernet 0/1 Dell Converged Enhanced Ethernet Command Reference 195 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 212
tree tc-flush-standard Operands none Defaults MAC address flushing is enabled. Command Global configuration mode Modes Description Use this command to flush the MAC address based on the See Also show spanning-tree brief 196 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 213
default is 6. Command Protocol Spanning Tree MSTP mode Modes Description Use this command to configure the BPDU burst size by changing the transmit hold count value. Use the no transmit 3 See Also show spanning-tree mst detail Dell Converged Enhanced Ethernet Command Reference 197 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 214
11 transmit-holdcount 198 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 215
VLAN interface to display the snooping configuration related information. The range of valid specific groups on specific interfaces. Usage There are no usage guidelines for this command. Guidelines Examples To clear information for all groups in the IGMP protocol: switch#clear ip igmp group Dell - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 216
12 clear ip igmp group See Also none 200 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 217
usage guidelines for this command. Guidelines Examples To clear information for all groups in the IGMP protocol: switch#clear ip igmp groups See Also none Dell Converged Enhanced Ethernet Command Reference 201 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 218
following interfaces: vlan vlan_id Specifies which VLAN interface to display the snooping configuration related information. The range of valid values is 1-3583. extengigabitethernet command. Example none See Also none 202 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 219
no defaults for this command. Command Privileged EXEC Mode Modes User Guidelines There are no user guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 203 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 220
defaults for this command. Command Privileged EXEC Mode Modes User Guidelines There are no user guidelines for this command. Example none See Also none 204 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 221
no defaults for this command. Command Privileged EXEC Mode Modes User Guidelines There are no user guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 205 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 222
snooping enable Operands none Defaults IGMP snooping is globally disabled. Command Global Configuration mode Modes Description Use this command to enable or disable the Internet , ip igmp snooping enable (VLAN version) 206 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 223
Protocol (IGMP) snooping for a specific VLAN interface. Synopsis ip igmp Configuration mode Modes Description Use this command to enable or disable the Internet Group Management Protocol (IGMP) snooping on a specific Examples To enable igmp for a specific VLAN interface, enter Interface VLAN mode - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 224
leave processing allows the removal of an interface from the forwarding-table without sending out group specific queries to the interface. Defaults This mode is disabled by default. Command Global Configuration mode Modes User Guidelines Use no ip igmp snooping fast-leave to disable this function - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 225
ip igmp snooping mrouter Configures a VLAN port member are no default configurations for this command. Command Privileged EXEC Mode Modes Description Use this command to configure a VLAN port return to the default setting. Guidelines Examples To configure a VLAN port member to be a multicast - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 226
ip igmp snooping mrouter-timeout ip igmp snooping mrouter-timeout Synopsis Operands Configures the mrouter-time-out ip igmp snooping mrouter-timeout seconds seconds Timeout for this command. Example none See Also none 210 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 227
the IGMP snooping querier feature: switch(conf-if-vl-1)#ip igmp snooping querier enable See Also show ip igmp interface, show ip igmp snooping interface Dell Converged Enhanced Ethernet Command Reference 211 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 228
12 ip igmp static-group ip igmp static-group Synopsis Configures the static group membership entries. ip igmp static-group A.B.C.D {interface [{in | ex}tengigabitethernet guidelines for this command. Example none See Also none 212 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 229
no defaults for this command. Command Privileged EXEC mode Modes User Guidelines There are no user guidelines for this command. Example none See Also none Dell Converged Enhanced Ethernet Command Reference 213 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 230
configured entries for either all groups on all interfaces, or all groups on specific interfaces, or specific groups on specific interfaces. Usage There are no usage guidelines for this command. Guidelines Examples none See Also none 214 Dell - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 231
of the following interfaces: Specifies which VLAN interface to display the snooping configuration related information. The range of valid values is 1-3583. mrouter interface vlan igmp snooping interface vlan 5 See Also none Dell Converged Enhanced Ethernet Command Reference 215 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 232
Operands none Description This command displays the IGMP contents of the currently running configuration. Note that this information may differ from the contents of the actual running this command. Example none See Also none 216 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 233
IP address 192.10.138.176 to which sFlow datagrams are forwarded: switch(conf-if-te-0/1)#sFlow collector 192.10.138.176 See Also none Dell Converged Enhanced Ethernet Command Reference 217 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 234
By default, sFlow is disabled on the system. Command Global configuration mode Modes Description Use this command to enable sFlow globally. Use sflow enable command to disable sFlow globally. Usage This command is supported on physical ports and Link Aggregation Group (LAG) ports. Guidelines - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 235
interface command to disable sFlow on an interface. Usage This command is supported on physical ports and Link Aggregation Groups (LAG) ports. After a Guidelines physical port is a member of a LAG, it inherits the sFlow configuration from the LAG port. Examples To enable sFlow on an interface - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 236
polling interval value is 20 seconds. Command Global configuration mode Modes Description Use this command to configure the polling interval globally. The interval is the See Also sflow polling interval (interface version) 220 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 237
value is 20 seconds. Command Interface Mode Modes Description Use this command to configure the polling interval for an interface. The interval is the maximum number of See Also sflow polling interval (global version) Dell Converged Enhanced Ethernet Command Reference 221 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 238
2-8388608 packets. Defaults The default sample rate is 32768 packets. Command Global configuration mode Modes Description Use this command to change the current global default sampling sflow sample-rate (interface version) 222 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 239
the number of packets that are skipped before the next sample is taken for a specific interface. sflow sample-rate sample rate no sflow sample-rate sample rate Specifies the sampling See Also sflow sample-rate (global version) Dell Converged Enhanced Ethernet Command Reference 223 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 240
no usage guidelines for this command. Guidelines Examples To display sFlow statistics: switch#show sflow sFlow services are enabled Global default sampling rate: 32768 Global default counter polling interval: 20 1 collectors configured Collector IP addr: 172.21.162.51, Agent IP addr: 10.32.152.22 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 241
Displays sFlow information on a specific interface. show sflow interface name this command to display sFlow information on a specific interface. Usage There are no usage guidelines for #>show sflow interface tengigabitethernet 1/16 te 1/16 Configured sampling rate :8192 Actual sampling rate :8192 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 242
13 show sflow interface 226 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 243
command to remove the description string. Example To set the string describing monitor session 1: sw0(config)#monitor session 1 sw0(config-mon-sess-1)#description server group 1 switch-cmsh See Also monitor session Dell Converged Enhanced Ethernet Command Reference 227 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 244
monitor transmitting and receiving traffic. Defaults There are no default configurations for this command. Command Modes Description Privileged EXEC Mode Use this 0/1 destination extengigabitethernet 0/15 direction both 228 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 245
The range of valid values is 0-65535. Defaults There are no default configurations for this command. Command Exec Mode Modes Description Use this command to Mirroring sessions: switch#show monitor See Also monitor session Dell Converged Enhanced Ethernet Command Reference 229 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 246
14 show monitor 230 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 247
. Command Global configuration mode Modes Description Use this command to set alarm conditions. Use the no rmon alarm command to disable the alarm conditions. Usage There are no usage guidelines for this command. Guidelines Examples To set alarm conditions: Dell Converged Enhanced Ethernet - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 248
15 rmon alarm See Also switch(config)#rmon alarm 100 1.3.6.1.2.1.16.1.1.1.5.65535 interval 5 absolute rising-threshold 10000 event 100 falling-threshold 1000 event 101 owner admin rmon event, show rmon 232 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 249
32. Defaults The collection of RMON history is not enabled. Command Interface configuration mode Modes Description Use this command to collect Ethernet group statistics on an collection history 5 See Also show rmon history Dell Converged Enhanced Ethernet Command Reference 233 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 250
owner. Defaults The collection of RMON statistics is not enabled. Command Interface configuration mode Modes Description Use this command to collect Ethernet group statistics on an owner admin See Also show rmon statistics 234 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 251
to identify this trap. Defaults There are no events configured. Command Global configuration mode Modes Description Use this command to add or remove to remove the event configuration. Usage There are no usage guidelines for this command. Guidelines Examples To configure an RMON event: switch - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 252
65535. Specifies a brief summary of the output. Defaults There are no default configurations for this command. Command EXEC mode Modes Description Use this command to display pkts: 0 Over 1518-byte pkts(Oversize - Jumbo): 0 236 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 253
"My Description" Event type Log & SnmpTrap Event community name admin Last Time Sent = 00:00:00 Owner admin rmon alarm, rmon event 15 show rmon Dell Converged Enhanced Ethernet Command Reference 237 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 254
collected by the rmon collection history command. Defaults There are no default configurations for this command. Command Privileged EXEC mode Modes User Guidelines Use the 20 sampling interval: 10 Owner: jsmith See Also none 238 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 255
is allowed. Defaults There is no CEE Provisioning applied on an interface. Command Interface configuration mode Modes Description Use this command to apply the CEE map on an interface. Use Map does not exist See Also cee-map Dell Converged Enhanced Ethernet Command Reference 239 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 256
CEE map is allowed, named "default". It is created when system starts up. The initial configuration of the default CEE map is: Precedence 1 Priority Group Table 1: Weight 40, PFC Enabled -group-table, priority-table, fcoe-map 240 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 257
. Usage A PGID value of 15 is a special value, which allows you to configure priorities with no bandwidth Guidelines limit. The priority groups 15.0-5.7 are pre-defined in the switch. See Also cee-map, priority-table, show qos Dell Converged Enhanced Ethernet Command Reference 241 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 258
matches the IEEE 802.1Q recommendation for systems supporting eight traffic classes. The 802.1Q maps CoS identical to the priority queue number. If your configuration violates this restriction an error message displays and the 1 242 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 259
incoming Priority-to-Priority Groups PGID 1 1 15.0 See Also switch(config)#ceemap test switch(conf-ceemap)#priority-table 1 1 0 1 1 1 1 15.0 cee, cee-map, priority-group-table Dell Converged Enhanced Ethernet Command Reference 243 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 260
Service (CoS) value. qos cos value no qos cos value Specifies the CoS value. The range of valid values is 0-7. Defaults The default CoS value is 0 (zero). Command Interface configuration See Also show qos, qos map, qos trust 244 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 261
mutation QoS map applied; by default the inbound CoS equals the outbound CoS. Command Interface configuration mode Modes Description Use this command to apply a CoS-to-CoS mutation QoS map on qos map cos-mutation, show qos maps Dell Converged Enhanced Ethernet Command Reference 245 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 262
behavior is to match the IEEE 802.1Q recommendations for systems supporting eight Traffic Classes. Command Interface configuration mode Modes Description Use this command to apply a CoS-to- qos cos-mutation, show qos maps 246 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 263
inbound CoS 7. Defaults There are no CoS-to-CoS mutation QoS maps defined. Command Global configuration mode Modes Description Use this command to create a QoS map for performing CoS-to-CoS )#no qos map cos-mutation test Dell Converged Enhanced Ethernet Command Reference 247 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 264
16 qos map cos-mutation See Also qos cos-mutation, show qos maps 248 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 265
Class QoS maps defined. Command Global configuration mode Modes Description Use this command to to a scheduler queue and packet servicing policy. Use the no qos IEEE 802.1Q for systems supporting eight Traffic Classes. Usage Dell Converged Enhanced Ethernet Command Reference 249 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 266
scheduler Synopsis Configures the multicast Traffic Class packet expansion scheduler policy. All multicast Traffic Class packet expansion queues are serviced Deficit Weighted packet expansion scheduler to the default value. 250 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 267
the system to the default multicast Traffic Class packet expansion scheduler policy: switch(config)#no qos queue multicast scheduler See Also qos rcv-queue multicast Dell Converged Enhanced Ethernet Command Reference 251 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 268
no qos queue scheduler strict-priority Configures the Strict Priority Traffic Class policy. All Strict Priority Traffic Classes are serviced before any DWRR Traffic Classes. strict The range of valid values is 0-100 percent. 252 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 269
policy. Eight Traffic Classes are supported with a configurable number of them being Strict Priority and any remaining ones being serviced DWRR. This Traffic Class packet queue scheduler See Also qos rcv-queue multicast Dell Converged Enhanced Ethernet Command Reference 253 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 270
egress interfaces on the switch. The range of valid values is 6500-20000000 pkt/s. Configures a cap on the maximum burst size for multicast packet expansion, for example packet replication limit See Also qos rcv-queue multicast 254 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 271
64 packets for each multicast Traffic Class. Command Global configuration mode Modes Description Use this command to configure a cap on the maximum queue depth for multicast packet threshold See Also qos rcv-queue multicast Dell Converged Enhanced Ethernet Command Reference 255 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 272
Defaults The QoS trust CoS mode set to the untrusted state. Command Interface configuration mode Modes Description Use this command to specify the interface ingress QoS trust mode mode See Also qos cos, show qos 256 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 273
Description Use this command to display information on a specified defined CEE map or on all of the defined CEE maps. For each CEE map, the configuration state is displayed with a list of all of the Layer 2 interfaces bound to the CEE map. Usage Fabric OS v6.3.1_cee only allows the CEE - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 274
mode Modes Description Use this command to display all of the configured flow control information for a specific interface. Usage Guidelines Use this command to display the runtime 0 1 Off Off Off Off 0 2 On Off On Off 0 258 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 275
See Also 3 Off Off Off Off 4 Off Off Off Off 5 Off Off Off Off 6 Off Off Off Off 7 Off Off Off Off show qos interface, show cee maps show qos flowcontrol interface 16 0 0 0 0 0 Dell Converged Enhanced Ethernet Command Reference 259 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 276
following interfaces: linecard portset slot chip Reports the QoS configuration for all 10 Gbps Ethernet interfaces within an ASIC. 4/4 5/4 6/4 7/4 Tail Drop Threshold 1081344 bytes Per-CoS Tail Drop Threshold (bytes) 260 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 277
6 7 Threshold: 64 64 64 64 64 64 64 64 Traffic Class Scheduler configured for 0 Strict Priority queues TrafficClass: 0 1 2 3 4 5 6 7 1 2 3 4 5 6 7 DWRRWeight: 25 25 25 25 25 25 25 25 cee-map, priority table Dell Converged Enhanced Ethernet Command Reference 261 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 278
information on the QoS defined maps. For each QoS map, the configuration state is displayed with a list of all interfaces bound to the 6 7 Enabled on the following interfaces: Te 0/5 See Also qos maps, show qos interface 262 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 279
bytes sent and received for each priority. Usage For a stand-alone switch, all ASICs are considered as slot number zero 0 0 4 0 0 4 0 0 5 0 0 5 0 0 6 0 0 6 0 0 7 0 0 7 0 0 See Also qos maps, cee-map Dell Converged Enhanced Ethernet Command Reference 263 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 280
Modes Description Use this command to display a summary of all QoS configurations applied to an Layer 2 Interface. This includes the QoS Provisioning 0 1081344 6 0 1081344 7 0 1081344 See Also show qos rcv-queue multicast 264 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 281
configurations for this command. Command EXEC mode Modes Description Use this command to display the runtime state information retrieved from the interface reflecting any multicast packet expansion packet drops resulting from a queue crossing the maximum queue depth. Usage For a stand-alone - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 282
16 show qos rcv-queue multicast 266 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 283
. Usage There are no usage guidelines for this command. Guidelines Examples To clear dot1x statistics: switch>clear dot1x statistics See Also clear dot1x statistics interface Dell Converged Enhanced Ethernet Command Reference 267 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 284
Modes Description Use this command to clear all of the dot1x statistics for a specific interface port. Usage There are no usage guidelines for this command. Guidelines Examples To 0/16 See Also clear dot1x statistics 268 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 285
Use the no dot1x authentication command to disable dot1x on the port and remove the configuration from 802.1X management. Usage There are no usage guidelines for this command. te-0/16)#dot1x authentication See Also none Dell Converged Enhanced Ethernet Command Reference 269 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 286
Operands none Defaults By default, authentication is disabled globally. Command Global configuration mode Modes Description Use this command to globally enable 802.1X authentication switch(config)#dot1x enable See Also none 270 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 287
in an unauthorized state. Defaults The default port state is auto. Command Interface configuration mode Modes Description Use this command to control the authorization of a port state. )#dot1x port-control auto See Also none Dell Converged Enhanced Ethernet Command Reference 271 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 288
of valid values is 1-65535. Defaults The default time is 60 seconds. Command Interface configuration mode Modes Description Use this command to set the time in seconds after which a 16)#dot1x quiet-period 200 See Also none 272 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 289
are no usage guidelines for this command. Guidelines Examples To initiate reauthentication on interface extengigabitethernet 0/16: switch#dot1x reauthenticate interface extengigabitethernet 0/16 See Also none Dell Converged Enhanced Ethernet Command Reference 273 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 290
Operands none Defaults There are no defaults for this command. Command Interface configuration mode Modes Description Use this command to enable reauthentication on a port conf-if-te-0/16)#dot1x reauthentication See Also none 274 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 291
The default number of times that a port attempts authentication is two. Command Interface configuration mode Modes Description Use this command to set the maximum number of times that -0/16)#no dot1x reauthMax See Also none Dell Converged Enhanced Ethernet Command Reference 275 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 292
values is 1-4294967295. Defaults The default time is 3600 seconds. Command Interface configuration mode Modes Description Use this command to set the number of seconds between )#dot1x timeout re-authperiod 25 See Also none 276 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 293
authentication server. The range of valid values is 1-65535. Defaults The default timeout is 30 seconds. Command Interface configuration mode server transmission time: switch(config)#interface extengigabitethernet 0/16 switch(conf-if-te-0/16)#dot1x timeout server-timeout 40 See Also none Dell - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 294
of valid values is 1-65535. Defaults The default timeout is 30 seconds. Command Interface configuration mode Modes Description Use this command to specify the EAP response timeout. Usage There supp-timeout 40 See Also none 278 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 295
valid values is 1-65535. Defaults The default timeout is 30 seconds. Command Interface configuration mode Modes Description Use this command to set the interval between successive attempts to tx-period 34 See Also none Dell Converged Enhanced Ethernet Command Reference 279 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 296
switch>show dot1x 802.1X Port-Based Authentication Enabled PAE Capability: Authenticator Only Protocol Version: 2 Auth Server: RADIUS RADIUS Configuration Position: Server Address: Port: Secret: Position: Server Address: Port: Secret: 1 172.21.162.51 1812 sharedsecret 2 10.32.154.113 1812 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 297
2 Auth Server: RADIUS RADIUS Configuration Position: Server Address: Port: Secret: 1 172.21.162.51 1812 sharedsecret Position: Server Address: : 30 seconds Quiet Period: 60 seconds Supplicant Timeout: 30 seconds Server Timeout: 30 seconds Re-Auth Interval: 3600 seconds PAE State: - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 298
17 show dot1x all See Also none 282 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 299
: 0 authEapstartWhileAuthenticated: 0 authEaplogoffWhileAuthenticated: 0 BackendResponses: 0 BackendAccessChallenges: 0 BackendOtherrequestToSupplicant: 0 BackendAuthSuccess: 0 BackendAuthFails: 0 See Also none Dell Converged Enhanced Ethernet Command Reference 283 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 300
: Disabled Auth Fail Max Attempts: 0 ReAuth Max: 2 Tx Period: 30 seconds Quiet Period: 60 seconds Supplicant Timeout: 30 seconds Server Timeout: 30 seconds Re-Auth Interval: 3600 seconds PAE State: Connected BE State: Invalid Supplicant Name: -- Supplicant Address: 0000.0000 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 301
extengigabitethernet 0/16 802.1X Session info for te0/16 User Name: testuser Session Time: 3 mins 34 secs Terminate Cause: Not terminated yet See Also none Dell Converged Enhanced Ethernet Command Reference 285 53-1002115-01 - Dell PowerEdge M520 | Dell Converged Enhanced Ethernet Command Reference - Page 302
: 0 Invalid EAPOL Frames Rx: 0 - EAP Length Error Frames Rx: 0 EAPOL Last Frame Version Rx: 0 - EAPOL Last Frame Src: 0000.0000.0000 See Also none 286 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01
53-1002115-01
07 December 2010
Dell Converged Enhanced
Ethernet Command
Reference