Page 236 highlights
13 sflow polling-interval (global version) sflow polling-interval (global version) Synopsis Operands Configures the polling interval globally. sflow polling-interval interval value no sflow polling-interval interval value Specifies a value in seconds to set the polling interval. The range of valid values is 1-65535. Defaults The default global counter polling interval value is 20 seconds. Command Global configuration mode Modes Description Use this command to configure the polling interval globally. The interval is the maximum number of seconds between successive samples of counters to be sent to the collector. Use the no sflow polling interval interval command to return to the default value. Usage There are no usage guidelines for this command. Guidelines Examples To set the polling interval to 135 seconds: switch(config)#sFlow polling interval 135 See Also sflow polling interval (interface version) 220 Dell Converged Enhanced Ethernet Command Reference 53-1002115-01