Dell PowerEdge M520 Dell Converged Enhanced Ethernet Command Reference - Page 291
dot1x reauthMax, Synopsis, Operands, Defaults, Command, Modes, Description, Usage, Guidelines
View all Dell PowerEdge M520 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 291 highlights
dot1x reauthMax 17 dot1x reauthMax Synopsis Operands Sets the maximum number of times that a port attempts to reauthenticate. dot1x reauthMax number no dot1x reauthMax number Specifies the maximum number of reauthentication attempts before the port goes to the unauthorized state. The range of valid values is 1-10. Defaults The default number of times that a port attempts authentication is two. Command Interface configuration mode Modes Description Use this command to set the maximum number of times that a port attempts to reauthenticate before a port changes to the unauthorized state. Use the no dot1x reauthMax command to return to the default setting. Usage There are no usage guidelines for this command. Guidelines Examples To set the maximum number of reauthentication attempts to 5: switch(config)#interface extengigabitethernet 0/16 switch(conf-if-te-0/16))#dot1x reauthMax 5 To set the reauthentication maximum to the default value: switch(config)#interface extengigabitethernet 0/16 switch(conf-if-te-0/16)#no dot1x reauthMax See Also none Dell Converged Enhanced Ethernet Command Reference 275 53-1002115-01