Strings, Anti-Curl, The Anti-Curl Strings are attached to the Jam Access Door Assembly
UPC - 088698569634
View all HP 8000dn manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 270 highlights
Strings, Anti-Curl Figure 6-77 Mailbox with Stapler, Anti-Curl String Lower Connection The Anti-Curl Strings are attached to the Jam Access Door Assembly at the top of the frame, routed through small pulleys at the back of the Delivery Head Assembly, and then routed around pulleys near the bottom of the frame where they are attached to tension springs. 1 Remove all paper bins and the blind cover (see figure 6-75 on page 244). 2 Disconnect the Anti-Curl String tension springs at the bottom of the frame (figure 6-77, callout 1), and remove the strings from the lower pulleys by snapping them free (figure 6-77, callout 2). 3 Remove both covers (see figure 6-54 on page 223). 4 Remove the Jam Access Door Assembly (see figure 6-63 on page 232 through figure 6-65 on page 234). 246 Chapter 6 Removal and Replacement EN