HP Cluster Platform Express v2010 Workgroup System and Cluster Platform Expres - Page 79

D.2 Administrative/Console Wiring Tables for One c7000 Enclosure with Double-Density Server Blades

Page 79 highlights

D.2 Administrative/Console Wiring Tables for One c7000 Enclosure with Double-Density Server Blades The following table provides the Administrative and Console wiring scheme for one c7000 enclosure with double-density server blades. Connections for the external control node and external InfiniBand switch are omitted if those components are not part of the configuration. Note: For the port labeling syntax for all of the cabling tables in this appendix, see Table A-1. Table D-1 One c7000 Enclosure with an External InfiniBand Switch, an External Control Node, and with Double-Density Server Blades Only (IMB1) Origin Label Enclosure 1, IMB1, E1-IMB1-P20 Port 20 Enclosure 1, IMB1, E1-IMB1-P21 Port 21 Enclosure 1, IMB1, E1-IMB1-P22 Port 22 Enclosure 1, IMB1, E1-IMB1-P23 Port 23 Enclosure 1, IMB1, E1-IMB1-P24 Port 24 IMB1 Destination Label Comment Enclosure 1, IMB2, Port E1-IMB2-P20 20 IB Switch 2 Ethernet IB-SW2-NIC Only used when 2nd InfiniBand Port switch is present Enclosure 1 OA1 E1-OA1-iLO Optional if there is no external control node IB Switch 1 Ethernet IB-SW1-NIC Only used when InfiniBand is Port present External Control Ethernet Port Control-NIC1 Only present with an external control node Table D-2 One c7000 Enclosure with an External InfiniBand Switch, an External Control Node, and with Double-Density Server Blades Only (IMB2) Origin Label Enclosure 1, IMB2, E1-IMB2-P20 Port 20 Enclosure 1, IMB1, E1-IMB1-P21 Port 21 IMB2 Destination Label Comment Enclosure 1, IMB1, Port E1-IMB1-P20 20 External control node Control-iLO Only present with an external iLO (optional) control node (optional connection) D.3 Administrative/Console Wiring Tables for Two or Three c7000 Enclosures with Single-Density Server Blades The following table provides the wiring scheme for the Administrative/Console/GigE networks in configurations of two and three c7000 enclosures using single-density server blades. For configurations with two c-Class enclosures, the wiring related to a third enclosure (E3) can be ignored. Table D-3 Administrative/Console Wiring Tables for Configurations with Two or Three c7000 Enclosures with Single-Density Server Blades Origin Label ProCurve 2824 Admin-ES1-P1 Port 1 ProCurve 2824 Admin-ES1-P2 Port 2 Destination Enclosure 1, IMB1, Port 21 Enclosure 1, IMB1, Port 22 Label Comment E1-IMB1-P21 E1-IMB1-P22 Only present if interconnect is GigE D.2 Administrative/Console Wiring Tables for One c7000 Enclosure with Double-Density Server Blades 79

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

D.2 Administrative/Console Wiring Tables for One c7000 Enclosure with
Double-Density Server Blades
The following table provides the Administrative and Console wiring scheme for one c7000
enclosure with double-density server blades. Connections for the external control node and
external InfiniBand switch are omitted if those components are not part of the configuration.
Note:
For the port labeling syntax for all of the cabling tables in this appendix, see
Table A-1
.
Table D-1 One c7000 Enclosure with an External InfiniBand Switch, an External Control Node, and
with Double-Density Server Blades Only (IMB1)
IMB1
Comment
Label
Destination
Label
Origin
E1-IMB2-P20
Enclosure 1, IMB2, Port
20
E1-IMB1-P20
Enclosure 1, IMB1,
Port 20
Only used when 2nd InfiniBand
switch is present
IB-SW2-NIC
IB Switch 2 Ethernet
Port
E1-IMB1-P21
Enclosure 1, IMB1,
Port 21
Optional if there is no external
control node
E1-OA1-iLO
Enclosure 1 OA1
E1-IMB1-P22
Enclosure 1, IMB1,
Port 22
Only used when InfiniBand is
present
IB-SW1-NIC
IB Switch 1 Ethernet
Port
E1-IMB1-P23
Enclosure 1, IMB1,
Port 23
Only present with an external
control node
Control-NIC1
External Control
Ethernet Port
E1-IMB1-P24
Enclosure 1, IMB1,
Port 24
Table D-2 One c7000 Enclosure with an External InfiniBand Switch, an External Control Node, and
with Double-Density Server Blades Only (IMB2)
IMB2
Comment
Label
Destination
Label
Origin
E1-IMB1-P20
Enclosure 1, IMB1, Port
20
E1-IMB2-P20
Enclosure 1, IMB2,
Port 20
Only present with an external
control node (optional connection)
Control-iLO
External control node
iLO (optional)
E1-IMB1-P21
Enclosure 1, IMB1,
Port 21
D.3 Administrative/Console Wiring Tables for Two or Three c7000
Enclosures with Single-Density Server Blades
The following table provides the wiring scheme for the Administrative/Console/GigE networks
in configurations of two and three c7000 enclosures using single-density server blades. For
configurations with two c-Class enclosures, the wiring related to a third enclosure (E3) can be
ignored.
Table D-3 Administrative/Console Wiring Tables for Configurations with Two or Three c7000
Enclosures with Single-Density Server Blades
Comment
Label
Destination
Label
Origin
E1-IMB1-P21
Enclosure 1, IMB1,
Port 21
Admin-ES1-P1
ProCurve 2824
Port 1
Only present if interconnect is GigE
E1-IMB1-P22
Enclosure 1, IMB1,
Port 22
Admin-ES1-P2
ProCurve 2824
Port 2
D.2 Administrative/Console Wiring Tables for One c7000 Enclosure with Double-Density Server Blades
79