From Label Enclosure 1 Interconnect Module 5/6 Port 5 E1-IMB5-P5 Enclosure 1 Interconnect Module 5/6 Port 6 E1-IMB5-P6 Enclosure 1 Interconnect Module 5/6 Port 7 E1-IMB5-P7 Enclosure 1 Interconnect E1-IMB5-P8 Module 5/6 Port 8 To Label Enclosure 1 Interconnect Module 7/8 Port 5 E1-IMB7-P5 Enclosure 1 Interconnect Module 7/8 Port 6 E1-IMB7-P6 Enclosure 1 Interconnect Module 7/8 Port 7 E1-IMB7-P7 Enclosure 1 Interconnect Module 7/8 Port 8 E1-IMB7-P8 Control Node InfiniBand HCA Control-P1 Comment Not used if the control node is a rack-mount server connected to the InfiniBand fabric Only used if the control node is a rack-mount server connected to the InfiniBand fabric D.11 One c7000 Enclosure with Double-Density Server Blades, the HP 4X DDR InfiniBand Switch Module, and an External InfiniBand Switch If the single c7000 enclosure configuration includes an external InfiniBand switch, the two HP 4X DDR InfiniBand switch modules are connected together through that switch. If the configuration also includes an external control node, the InfiniBand HCA in the control node is connected to Port 24 of the external InfiniBand switch. From Label IB 24 Port Switch Port 1 IB-SW1-P1 IB 24 Port Switch Port 2 IB-SW1-P2 IB 24 Port Switch Port 3 IB-SW1-P3 IB 24 Port Switch Port 4 IB-SW1-P4 IB 24 Port Switch Port 5 IB-SW1-P5 IB 24 Port Switch Port 6 IB-SW1-P6 IB 24 Port Switch Port 7 IB-SW1-P7 IB 24 Port Switch Port 8 IB-SW1-P8 IB 24 Port Switch Port 9 IB-SW1-P9 IB 24 Port Switch Port 10 IB-SW1-P10 IB 24 Port Switch Port 11 IB-SW1-P11 IB 24 Port Switch Port 12 IB-SW1-P12 To Label Enclosure 1 Interconnect Module 5/6 Port 1 E1-IMB5-P1 Enclosure 1 Interconnect Module 5/6 Port 2 E1-IMB5-P2 Enclosure 1 Interconnect Module 5/6 Port 3 E1-IMB5-P3 Enclosure 1 Interconnect Module 5/6 Port 4 E1-IMB5-P4 Enclosure 1 Interconnect Module 5/6 Port 5 E1-IMB5-P5 Enclosure 1 Interconnect Module 5/6 Port 6 E1-IMB5-P6 Enclosure 1 Interconnect Module 5/6 Port 7 E1-IMB5-P7 Enclosure 1 Interconnect Module 5/6 Port 8 E1-IMB5-P8 Enclosure 1 Interconnect Module 7/8 Port 1 E1-IMB7-P1 Enclosure 1 Interconnect Module 7/8 Port 2 E1-IMB7-P2 Enclosure 1 Interconnect Module 7/8 Port 3 E1-IMB7-P3 Enclosure 1 Interconnect Module 7/8 Port 4 E1-IMB7-P4 Comment D.11 One c7000 Enclosure with Double-Density Server Blades, the HP 4X DDR InfiniBand Switch Module, and an External 91 InfiniBand Switch

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

Comment
Label
To
Label
From
E1-IMB7-P5
Enclosure 1 Interconnect
Module 7/8 Port 5
E1-IMB5-P5
Enclosure 1
Interconnect
Module 5/6 Port 5
E1-IMB7-P6
Enclosure 1 Interconnect
Module 7/8 Port 6
E1-IMB5-P6
Enclosure 1
Interconnect
Module 5/6 Port 6
E1-IMB7-P7
Enclosure 1 Interconnect
Module 7/8 Port 7
E1-IMB5-P7
Enclosure 1
Interconnect
Module 5/6 Port 7
Not used if the control node is a
rack-mount server connected to the
InfiniBand fabric
E1-IMB7-P8
Enclosure 1 Interconnect
Module 7/8 Port 8
E1-IMB5-P8
Enclosure 1
Interconnect
Module 5/6 Port 8
Only used if the control node is a
rack-mount server connected to the
InfiniBand fabric
Control-P1
Control Node InfiniBand
HCA
D.11 One c7000 Enclosure with Double-Density Server Blades, the HP 4X
DDR InfiniBand Switch Module, and an External InfiniBand Switch
If the single c7000 enclosure configuration includes an external InfiniBand switch, the two HP
4X DDR InfiniBand switch modules are connected together through that switch. If the
configuration also includes an external control node, the InfiniBand HCA in the control node is
connected to Port 24 of the external InfiniBand switch.
Comment
Label
To
Label
From
E1-IMB5-P1
Enclosure 1 Interconnect
Module 5/6 Port 1
IB-SW1-P1
IB 24 Port Switch
Port 1
E1-IMB5-P2
Enclosure 1 Interconnect
Module 5/6 Port 2
IB-SW1-P2
IB 24 Port Switch
Port 2
E1-IMB5-P3
Enclosure 1 Interconnect
Module 5/6 Port 3
IB-SW1-P3
IB 24 Port Switch
Port 3
E1-IMB5-P4
Enclosure 1 Interconnect
Module 5/6 Port 4
IB-SW1-P4
IB 24 Port Switch
Port 4
E1-IMB5-P5
Enclosure 1 Interconnect
Module 5/6 Port 5
IB-SW1-P5
IB 24 Port Switch
Port 5
E1-IMB5-P6
Enclosure 1 Interconnect
Module 5/6 Port 6
IB-SW1-P6
IB 24 Port Switch
Port 6
E1-IMB5-P7
Enclosure 1 Interconnect
Module 5/6 Port 7
IB-SW1-P7
IB 24 Port Switch
Port 7
E1-IMB5-P8
Enclosure 1 Interconnect
Module 5/6 Port 8
IB-SW1-P8
IB 24 Port Switch
Port 8
E1-IMB7-P1
Enclosure 1 Interconnect
Module 7/8 Port 1
IB-SW1-P9
IB 24 Port Switch
Port 9
E1-IMB7-P2
Enclosure 1 Interconnect
Module 7/8 Port 2
IB-SW1-P10
IB 24 Port Switch
Port 10
E1-IMB7-P3
Enclosure 1 Interconnect
Module 7/8 Port 3
IB-SW1-P11
IB 24 Port Switch
Port 11
E1-IMB7-P4
Enclosure 1 Interconnect
Module 7/8 Port 4
IB-SW1-P12
IB 24 Port Switch
Port 12
D.11 One c7000 Enclosure with Double-Density Server Blades, the HP 4X DDR InfiniBand Switch Module, and an External
InfiniBand Switch
91