HP Cluster Platform Express v2010 Workgroup System and Cluster Platform Expres - Page 82

D.5 Administrative/Console Wiring Tables for Three c7000 Enclosures with Double-Density Server Blades

Page 82 highlights

Table D-4 Administrative/Console Wiring Tables for Configurations with Two c7000 Enclosures with Double-Density Server Blades (continued) Origin Label Destination Label Comment ProCurve 2824 Admin-ES1-P20 Enclosure 2 OA1 Port 20 OA/iLO E3-OA1-iLO ProCurve 2824 Admin-ES1-P21 Enclosure 1 OA1 Port 21 OA/iLO E3-OA1-iLO ProCurve 2824 Admin-ES1-P22 Optional External Control- NIC1 Only present if the control node is not Port 22 Control Node NIC1 a server blade ProCurve 2824 Admin-ES1-P23 InfiniBand Switch 1 IB-SW1-NIC Only present if the interconnect is Port 23 Management Port InfiniBand ProCurve 2824 Admin-ES1-P24 Optional External Port 24 Control Node iLO Control-iLO Optional connection D.5 Administrative/Console Wiring Tables for Three c7000 Enclosures with Double-Density Server Blades The following table provides the Administrative/Console wiring scheme for three c7000 enclosures with double-density server blades in a system that does not include an InfiniBand fabric as the interconnect. Connections for the external control node are omitted if those components are not specified in the configuration. From Label ProCurve 2848 Port 1 Admin-ES1-P1 ProCurve 2848 Port 2 Admin-ES1-P2 ProCurve 2848 Port 3 Admin-ES1-P3 ProCurve 2848 Port 4 Admin-ES1-P4 ProCurve 2848 Port 5 ProCurve 2848 Port 6 Admin-ES1-P6 ProCurve 2848 Port 7 Admin-ES1-P7 ProCurve 2848 Port 8 Admin-ES1-P8 ProCurve 2848 Port 9 Admin-ES1-P9 ProCurve 2848 Port 10 To Label Comment Enclosure 1 Interconnect Module E1-IMB1-P21 1 Port 21 Enclosure 1 Interconnect Module E1-IMB1-P22 1 Port 22 Enclosure 1 Interconnect Module E1-IMB1-P23 1 Port 23 Enclosure 1 Interconnect Module E1-IMB1-P24 1 Port 24 Not Connected Enclosure 2 Interconnect Module E2-IMB1-P21 1 Port 21 Enclosure 2 Interconnect Module E2-IMB1-P22 1 Port 22 Enclosure 2 Interconnect Module E2-IMB1-P23 1 Port 23 Enclosure 2 Interconnect Module E2-IMB1-P24 1 Port 24 Not Connected 82 Cabling Tables for CPE BladeSystem, with c7000 Enclosure Configurations

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

Table D-4 Administrative/Console Wiring Tables for Configurations with Two c7000 Enclosures
with Double-Density Server Blades
(continued)
Comment
Label
Destination
Label
Origin
E3-OA1-iLO
Enclosure 2 OA1
OA/iLO
Admin-ES1-P20
ProCurve 2824
Port 20
E3-OA1-iLO
Enclosure 1 OA1
OA/iLO
Admin-ES1-P21
ProCurve 2824
Port 21
Only present if the control node is not
a server blade
Control- NIC1
Optional External
Control Node NIC1
Admin-ES1-P22
ProCurve 2824
Port 22
Only present if the interconnect is
InfiniBand
IB-SW1-NIC
InfiniBand Switch 1
Management Port
Admin-ES1-P23
ProCurve 2824
Port 23
Optional connection
Control-iLO
Optional External
Control Node iLO
Admin-ES1-P24
ProCurve 2824
Port 24
D.5 Administrative/Console Wiring Tables for Three c7000 Enclosures
with Double-Density Server Blades
The following table provides the Administrative/Console wiring scheme for three c7000 enclosures
with double-density server blades in a system that does not include an InfiniBand fabric as the
interconnect. Connections for the external control node are omitted if those components are not
specified in the configuration.
Comment
Label
To
Label
From
E1-IMB1-P21
Enclosure 1
Interconnect Module
1 Port 21
Admin-ES1-P1
ProCurve 2848
Port 1
E1-IMB1-P22
Enclosure 1
Interconnect Module
1 Port 22
Admin-ES1-P2
ProCurve 2848
Port 2
E1-IMB1-P23
Enclosure 1
Interconnect Module
1 Port 23
Admin-ES1-P3
ProCurve 2848
Port 3
E1-IMB1-P24
Enclosure 1
Interconnect Module
1 Port 24
Admin-ES1-P4
ProCurve 2848
Port 4
Not Connected
ProCurve 2848
Port 5
E2-IMB1-P21
Enclosure 2
Interconnect Module
1 Port 21
Admin-ES1-P6
ProCurve 2848
Port 6
E2-IMB1-P22
Enclosure 2
Interconnect Module
1 Port 22
Admin-ES1-P7
ProCurve 2848
Port 7
E2-IMB1-P23
Enclosure 2
Interconnect Module
1 Port 23
Admin-ES1-P8
ProCurve 2848
Port 8
E2-IMB1-P24
Enclosure 2
Interconnect Module
1 Port 24
Admin-ES1-P9
ProCurve 2848
Port 9
Not Connected
ProCurve 2848
Port 10
82
Cabling Tables for CPE BladeSystem, with c7000 Enclosure Configurations