HP Cluster Platform Express v2010 Workgroup System and Cluster Platform Expres - Page 85

the interconnect. Connections for the external control node and external InfiniBand switches are

Page 85 highlights

the interconnect. Connections for the external control node and external InfiniBand switches are omitted if those components are not specified in the configuration. From ProCurve 2824 Port 1 ProCurve 2824 Port 2 ProCurve 2824 Port 3 ProCurve 2824 Port 4 ProCurve 2824 Port 5 ProCurve 2824 Port 6 ProCurve 2824 Port 7 ProCurve 2824 Port 8 ProCurve 2824 Port 9 ProCurve 2824 Port 10 ProCurve 2824 Port 11 ProCurve 2824 Port 12 ProCurve 2824 Port 13 ProCurve 2824 Port 14 ProCurve 2824 Port 15 ProCurve 2824 Port 16 ProCurve 2824 Port 17 ProCurve 2824 Port 18 ProCurve 2824 Port 19 ProCurve 2824 Port 20 Label Admin-ES1-P1 Admin-ES1-P2 Admin-ES1-P3 To Label Enclosure 1 Interconnect Module E1-IMB1-P21 1 Port 21 Enclosure 2 Interconnect Module E2-IMB1-P21 1 Port 21 Enclosure 3 Interconnect Module E3-IMB1-P21 1 Port 21 Not Connected Not Connected Not Connected Not Connected Not Connected Not Connected Not Connected Admin-ES1-P11 Admin-ES1-P12 Admin-ES1-P13 Enclosure 1 Interconnect Module E1-IMB2-P21 2 Port 21 Enclosure 2 Interconnect Module E2-IMB2-P21 2 Port 21 Enclosure 3 Interconnect Module E3-IMB2-P21 2 Port 21 Not Connected Admin-ES1-P15 InfiniBand Switch 2 Management Port IB-SW2-NIC Not Connected Not Connected Not Connected Admin-ES1-P19 Admin-ES1-P20 Enclosure 3 OA1 OA/ILO Enclosure 2 OA1 OA/ILO E3-OA1-ILO E2-OA1-ILO Comment Only used when a second external managed InfiniBand switch is present D.6 Administrative/Console Wiring Tables for Three c7000 Enclosures with Double-Density Server Blades and the InfiniBand 85 Fabric

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

the interconnect. Connections for the external control node and external InfiniBand switches are
omitted if those components are not specified in the configuration.
Comment
Label
To
Label
From
E1-IMB1-P21
Enclosure 1
Interconnect Module
1 Port 21
Admin-ES1-P1
ProCurve 2824
Port 1
E2-IMB1-P21
Enclosure 2
Interconnect Module
1 Port 21
Admin-ES1-P2
ProCurve 2824
Port 2
E3-IMB1-P21
Enclosure 3
Interconnect Module
1 Port 21
Admin-ES1-P3
ProCurve 2824
Port 3
Not Connected
ProCurve 2824
Port 4
Not Connected
ProCurve 2824
Port 5
Not Connected
ProCurve 2824
Port 6
Not Connected
ProCurve 2824
Port 7
Not Connected
ProCurve 2824
Port 8
Not Connected
ProCurve 2824
Port 9
Not Connected
ProCurve 2824
Port 10
E1-IMB2-P21
Enclosure 1
Interconnect Module
2 Port 21
Admin-ES1-P11
ProCurve 2824
Port 11
E2-IMB2-P21
Enclosure 2
Interconnect Module
2 Port 21
Admin-ES1-P12
ProCurve 2824
Port 12
E3-IMB2-P21
Enclosure 3
Interconnect Module
2 Port 21
Admin-ES1-P13
ProCurve 2824
Port 13
Not Connected
ProCurve 2824
Port 14
Only used when a second external
managed InfiniBand switch is
present
IB-SW2-NIC
InfiniBand Switch 2
Management Port
Admin-ES1-P15
ProCurve 2824
Port 15
Not Connected
ProCurve 2824
Port 16
Not Connected
ProCurve 2824
Port 17
Not Connected
ProCurve 2824
Port 18
E3-OA1-ILO
Enclosure 3 OA1
OA/ILO
Admin-ES1-P19
ProCurve 2824
Port 19
E2-OA1-ILO
Enclosure 2 OA1
OA/ILO
Admin-ES1-P20
ProCurve 2824
Port 20
D.6 Administrative/Console Wiring Tables for Three c7000 Enclosures with Double-Density Server Blades and the InfiniBand
Fabric
85