D.8 InfiniBand Wiring Table for Two c7000 Enclosures with Single-Density Blades (Without an External InfiniBand Switch)

Page 88 highlights

From Label IB 24 Port Switch Port 18 IB-SW1-P18 IB 24 Port Switch Port 19 IB-SW1-P19 IB 24 Port Switch Port 20 IB-SW1-P20 IB 24 Port Switch Port 21 IB-SW1-P21 IB 24 Port Switch Port 22 IB-SW1-P22 IB 24 Port Switch Port 23 IB-SW1-P23 IB 24 Port Switch Port 24 IB-SW1-P24 To N/A N/A N/A N/A N/A N/A N/A Label N/A N/A N/A N/A N/A N/A N/A Comment D.8 InfiniBand Wiring Table for Two c7000 Enclosures with Single-Density Blades (Without an External InfiniBand Switch) The following table specifies the wiring scheme for a configuration with two c7000 enclosures wired back-to-back using the HP 4X DDR InfiniBand switch module. The connection to Enclosure 1, Interconnect Module 5/6, Port 8 depends on whether the configuration includes an external control node connected to the InfiniBand fabric or not. If there is a control node connected to the InfiniBand fabric, the control node's HCA is connected to Port 8 on the InfiniBand switch installed in Interconnect Module Bay 5/6 of the c7000 enclosure. Otherwise, that port is connected to Port 8 on the InfiniBand switch installed in Interconnect Module Bay 5/6 in Enclosure 2. From Label Enclosure 1 Interconnect Module 5/6 Port 1 E1-IMB5-P1 Enclosure 1 Interconnect Module 5/6 Port 2 E1-IMB5-P2 Enclosure 1 Interconnect Module 5/6 Port 3 E1-IMB5-P3 Enclosure 1 Interconnect Module 5/6 Port 4 E1-IMB5-P4 Enclosure 1 Interconnect Module 5/6 Port 5 E1-IMB5-P5 Enclosure 1 Interconnect Module 5/6 Port 6 E1-IMB5-P6 Enclosure 1 Interconnect Module 5/6 Port 7 E1-IMB5-P7 To Label Enclosure 2 Interconnect Module 5/6 Port 1 E2-IMB5-P1 Enclosure 2 Interconnect Module 5/6 Port 2 E2-IMB5-P2 Enclosure 2 Interconnect Module 5/6 Port 3 E2-IMB5-P3 Enclosure 2 Interconnect Module 5/6 Port 4 E2-IMB5-P4 Enclosure 2 Interconnect Module 5/6 Port 5 E2-IMB5-P5 Enclosure 2 Interconnect Module 5/6 Port 6 E2-IMB5-P6 Enclosure 2 Interconnect Module 5/6 Port 7 E2-IMB5-P7 Comments 88 Cabling Tables for CPE BladeSystem, with c7000 Enclosure Configurations

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

Comment
Label
To
Label
From
N/A
N/A
IB-SW1-P18
IB 24 Port Switch
Port 18
N/A
N/A
IB-SW1-P19
IB 24 Port Switch
Port 19
N/A
N/A
IB-SW1-P20
IB 24 Port Switch
Port 20
N/A
N/A
IB-SW1-P21
IB 24 Port Switch
Port 21
N/A
N/A
IB-SW1-P22
IB 24 Port Switch
Port 22
N/A
N/A
IB-SW1-P23
IB 24 Port Switch
Port 23
N/A
N/A
IB-SW1-P24
IB 24 Port Switch
Port 24
D.8 InfiniBand Wiring Table for Two c7000 Enclosures with Single-Density
Blades (Without an External InfiniBand Switch)
The following table specifies the wiring scheme for a configuration with two c7000 enclosures
wired back-to-back using the HP 4X DDR InfiniBand switch module. The connection to Enclosure
1, Interconnect Module 5/6, Port 8 depends on whether the configuration includes an external
control node connected to the InfiniBand fabric or not. If there is a control node connected to the
InfiniBand fabric, the control node’s HCA is connected to Port 8 on the InfiniBand switch installed
in Interconnect Module Bay 5/6 of the c7000 enclosure. Otherwise, that port is connected to Port
8 on the InfiniBand switch installed in Interconnect Module Bay 5/6 in Enclosure 2.
Comments
Label
To
Label
From
E2-IMB5-P1
Enclosure 2 Interconnect
Module 5/6 Port 1
E1-IMB5-P1
Enclosure 1
Interconnect
Module 5/6 Port 1
E2-IMB5-P2
Enclosure 2 Interconnect
Module 5/6 Port 2
E1-IMB5-P2
Enclosure 1
Interconnect
Module 5/6 Port 2
E2-IMB5-P3
Enclosure 2 Interconnect
Module 5/6 Port 3
E1-IMB5-P3
Enclosure 1
Interconnect
Module 5/6 Port 3
E2-IMB5-P4
Enclosure 2 Interconnect
Module 5/6 Port 4
E1-IMB5-P4
Enclosure 1
Interconnect
Module 5/6 Port 4
E2-IMB5-P5
Enclosure 2 Interconnect
Module 5/6 Port 5
E1-IMB5-P5
Enclosure 1
Interconnect
Module 5/6 Port 5
E2-IMB5-P6
Enclosure 2 Interconnect
Module 5/6 Port 6
E1-IMB5-P6
Enclosure 1
Interconnect
Module 5/6 Port 6
E2-IMB5-P7
Enclosure 2 Interconnect
Module 5/6 Port 7
E1-IMB5-P7
Enclosure 1
Interconnect
Module 5/6 Port 7