HP Cluster Platform Express v2010 Workgroup System and Cluster Platform Expres - Page 86

D.7 One c7000 Enclosure with Single-Density Blades and an HP 4x DDR InfiniBand Switch Module

Page 86 highlights

From ProCurve 2824 Port 21 ProCurve 2824 Port 22 ProCurve 2824 Port 23 ProCurve 2824 Port 24 Label Admin-ES1-P21 Admin-ES1-P22 Admin-ES1-P23 Admin-ES1-P24 To Label Comment Enclosure 1 OA1 OA/ILO E1-OA1-ILO Optional External Control Node NIC1 Control- NIC1 Only Ppresent if control node is not a server blade InfiniBand Switch 1 Management Port IB-SW1-NIC Only used when an external managed InfiniBand switch is present Optional external control node iLO Control-iLO Optional connection D.7 One c7000 Enclosure with Single-Density Blades and an HP 4x DDR InfiniBand Switch Module The following table specifies the wiring scheme for a configuration of one c7000 enclosure with single-density server blades using the HP 4x DDR InfiniBand switch module. The table shows the optional connections for an external control node attached to the InfiniBand fabric and for an external InfiniBand switch that may be included to provide InfiniBand fabric management. If either of these components are not present in the configuration or if the control node is not to be connected to the InfiniBand fabric, the associated connections are omitted. c7000 Enclosure Wiring From Label Enclosure 1 Interconnect Module 5/6 Port 1 E1-IMB5-P1 Enclosure 1 Interconnect Module 5/6 Port 2 E1-IMB5-P2 Enclosure 1 Interconnect Module 5/6 Port 3 E1-IMB5-P3 Enclosure 1 Interconnect Module 5/6 Port 4 E1-IMB5-P4 Enclosure 1 Interconnect Module 5/6 Port 5 E1-IMB5-P5 Enclosure 1 Interconnect Module 5/6 Port 6 E1-IMB5-P6 To Label InfiniBand 24-port Switch Port 1 IB-SW1-P1 Comment Only present if using a managed 24-port switch for Subnet Management instead of a Host-Based Subnet Manager N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 86 Cabling Tables for CPE BladeSystem, with c7000 Enclosure Configurations

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

Comment
Label
To
Label
From
E1-OA1-ILO
Enclosure 1 OA1
OA/ILO
Admin-ES1-P21
ProCurve 2824
Port 21
Only Ppresent if control node is not
a server blade
Control- NIC1
Optional External
Control Node NIC1
Admin-ES1-P22
ProCurve 2824
Port 22
Only used when an external
managed InfiniBand switch is
present
IB-SW1-NIC
InfiniBand Switch 1
Management Port
Admin-ES1-P23
ProCurve 2824
Port 23
Optional connection
Control-iLO
Optional external
control node iLO
Admin-ES1-P24
ProCurve 2824
Port 24
D.7 One c7000 Enclosure with Single-Density Blades and an HP 4x DDR
InfiniBand Switch Module
The following table specifies the wiring scheme for a configuration of one c7000 enclosure with
single-density server blades using the HP 4x DDR InfiniBand switch module. The table shows
the optional connections for an external control node attached to the InfiniBand fabric and for
an external InfiniBand switch that may be included to provide InfiniBand fabric management.
If either of these components are not present in the configuration or if the control node is not to
be connected to the InfiniBand fabric, the associated connections are omitted.
c7000 Enclosure Wiring
Comment
Label
To
Label
From
Only present if using a managed
24-port switch for Subnet
Management instead of a Host-Based
Subnet Manager
IB-SW1-P1
InfiniBand 24-port
Switch Port 1
E1-IMB5-P1
Enclosure 1
Interconnect
Module 5/6 Port
1
N/A
N/A
E1-IMB5-P2
Enclosure 1
Interconnect
Module 5/6 Port
2
N/A
N/A
E1-IMB5-P3
Enclosure 1
Interconnect
Module 5/6 Port
3
N/A
N/A
E1-IMB5-P4
Enclosure 1
Interconnect
Module 5/6 Port
4
N/A
N/A
E1-IMB5-P5
Enclosure 1
Interconnect
Module 5/6 Port
5
N/A
N/A
E1-IMB5-P6
Enclosure 1
Interconnect
Module 5/6 Port
6
86
Cabling Tables for CPE BladeSystem, with c7000 Enclosure Configurations