HP Cluster Platform Express v2010 Workgroup System and Cluster Platform Expres - Page 81

D.4 Administrative/Console Wiring Tables for Two c7000 Enclosures with Double-Density Server Blades

Page 81 highlights

D.4 Administrative/Console Wiring Tables for Two c7000 Enclosures with Double-Density Server Blades The following table provides the Administrative/Console wiring scheme for two c7000 enclosures with double-density server blades. Connections for the external control node and external InfiniBand switches are omitted if those components are not specified in the configuration. Table D-4 Administrative/Console Wiring Tables for Configurations with Two c7000 Enclosures with Double-Density Server Blades Origin Label Destination Label Comment ProCurve 2824 Admin-ES1-P1 Enclosure 1, IMB1, E1-IMB1-P21 Port 1 Port 21 ProCurve 2824 Admin-ES1-P2 Enclosure 1, IMB1, E1-IMB1-P22 Only present if interconnect is GigE Port 2 Port 22 ProCurve 2824 Admin-ES1-P3 Enclosure 1, IMB1, E1-IMB1-P23 Only present if interconnect is GigE Port 3 Port 23 ProCurve 2824 Admin-ES1-P4 Enclosure 1, IMB1, E1-IMB1-P24 Only present if interconnect is GigE Port 4 Port 24 ProCurve 2824 Admin-ES1-P5 Port 5 InfiniBand Switch 4 Management Port IB-SW4-NIC Only present if the interconnect is InfiniBand and the HP BLc 4X DDR InfiniBand Gen2 switch is used ProCurve 2824 Admin-ES1-P6 Enclosure 2, IMB1, E2-IMB1-P21 Port 6 Port 21 ProCurve 2824 Admin-ES1-P7 Enclosure 2, IMB1, E2-IMB1-P22 Only present if interconnect is GigE Port 7 Port 22 ProCurve 2824 Admin-ES1-P8 Enclosure 2, IMB1, E2-IMB1-P23 Only present if interconnect is GigE Port 8 Port 23 ProCurve 2824 Admin-ES1-P9 Enclosure 2, IMB1, E2-IMB1-P24 Only present if interconnect is GigE Port 9 Port 24 ProCurve 2824 Port 10 Admin-ES1-P10 InfiniBand Switch 3 Management Port IB-SW3-NIC Only present if the interconnect is InfiniBand and the HP BLc 4X DDR InfiniBand Gen2 switch is used ProCurve 2824 Admin-ES1-P11 Enclosure 1, IMB1, E3-IMB1-P21 Port 11 Port 21 ProCurve 2824 Admin-ES1-P12 Enclosure 1, IMB1, E3-IMB1-P22 Only present if interconnect is GigE Port 12 Port 22 ProCurve 2824 Admin-ES1-P13 Enclosure 1, IMB1, E3-IMB1-P23 Only present if interconnect is GigE Port 13 Port 23 ProCurve 2824 Admin-ES1-P14 Enclosure 1, IMB1, E3-IMB1-P24 Only present if interconnect is GigE Port 14 Port 24 ProCurve 2824 Admin-ES1-P15 InfiniBand Switch 2 IB-SW2-NIC Only present if the interconnect is Port 15 Management Port InfiniBand. ProCurve 2824 Admin-ES1-P16 Enclosure 2, IMB2, E2-IMB2-P21 Port 16 Port 21 ProCurve 2824 Admin-ES1-P17 Enclosure 2, IMB2, E2-IMB2-P22 Only present if interconnect is GigE Port 17 Port 22 ProCurve 2824 Admin-ES1-P18 Enclosure 2, IMB2, E2-IMB2-P23 Only present if interconnect is GigE Port 18 Port 23 ProCurve 2824 Admin-ES1-P19 Enclosure 2, IMB2, E2-IMB2-P24 Only present if interconnect is GigE Port 19 Port 24 D.4 Administrative/Console Wiring Tables for Two c7000 Enclosures with Double-Density Server Blades 81

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

D.4 Administrative/Console Wiring Tables for Two c7000 Enclosures with
Double-Density Server Blades
The following table provides the Administrative/Console wiring scheme for two c7000 enclosures
with double-density server blades. Connections for the external control node and external
InfiniBand switches are omitted if those components are not specified in the configuration.
Table D-4 Administrative/Console Wiring Tables for Configurations with Two c7000 Enclosures
with Double-Density Server Blades
Comment
Label
Destination
Label
Origin
E1-IMB1-P21
Enclosure 1, IMB1,
Port 21
Admin-ES1-P1
ProCurve 2824
Port 1
Only present if interconnect is GigE
E1-IMB1-P22
Enclosure 1, IMB1,
Port 22
Admin-ES1-P2
ProCurve 2824
Port 2
Only present if interconnect is GigE
E1-IMB1-P23
Enclosure 1, IMB1,
Port 23
Admin-ES1-P3
ProCurve 2824
Port 3
Only present if interconnect is GigE
E1-IMB1-P24
Enclosure 1, IMB1,
Port 24
Admin-ES1-P4
ProCurve 2824
Port 4
Only present if the interconnect is
InfiniBand and the HP BLc 4X DDR
InfiniBand Gen2 switch is used
IB-SW4-NIC
InfiniBand Switch 4
Management Port
Admin-ES1-P5
ProCurve 2824
Port 5
E2-IMB1-P21
Enclosure 2, IMB1,
Port 21
Admin-ES1-P6
ProCurve 2824
Port 6
Only present if interconnect is GigE
E2-IMB1-P22
Enclosure 2, IMB1,
Port 22
Admin-ES1-P7
ProCurve 2824
Port 7
Only present if interconnect is GigE
E2-IMB1-P23
Enclosure 2, IMB1,
Port 23
Admin-ES1-P8
ProCurve 2824
Port 8
Only present if interconnect is GigE
E2-IMB1-P24
Enclosure 2, IMB1,
Port 24
Admin-ES1-P9
ProCurve 2824
Port 9
Only present if the interconnect is
InfiniBand and the HP BLc 4X DDR
InfiniBand Gen2 switch is used
IB-SW3–NIC
InfiniBand Switch 3
Management Port
Admin-ES1-P10
ProCurve 2824
Port 10
E3-IMB1-P21
Enclosure 1, IMB1,
Port 21
Admin-ES1-P11
ProCurve 2824
Port 11
Only present if interconnect is GigE
E3-IMB1-P22
Enclosure 1, IMB1,
Port 22
Admin-ES1-P12
ProCurve 2824
Port 12
Only present if interconnect is GigE
E3-IMB1-P23
Enclosure 1, IMB1,
Port 23
Admin-ES1-P13
ProCurve 2824
Port 13
Only present if interconnect is GigE
E3-IMB1-P24
Enclosure 1, IMB1,
Port 24
Admin-ES1-P14
ProCurve 2824
Port 14
Only present if the interconnect is
InfiniBand.
IB-SW2-NIC
InfiniBand Switch 2
Management Port
Admin-ES1-P15
ProCurve 2824
Port 15
E2-IMB2–P21
Enclosure 2, IMB2,
Port 21
Admin-ES1-P16
ProCurve 2824
Port 16
Only present if interconnect is GigE
E2-IMB2–P22
Enclosure 2, IMB2,
Port 22
Admin-ES1-P17
ProCurve 2824
Port 17
Only present if interconnect is GigE
E2-IMB2–P23
Enclosure 2, IMB2,
Port 23
Admin-ES1-P18
ProCurve 2824
Port 18
Only present if interconnect is GigE
E2-IMB2–P24
Enclosure 2, IMB2,
Port 24
Admin-ES1-P19
ProCurve 2824
Port 19
D.4 Administrative/Console Wiring Tables for Two c7000 Enclosures with Double-Density Server Blades
81