HP Integrity rx2800 Installation Guide, Windows Server 2008 R2 v7.0 - Page 103

The SMH Home Overall Status Summary, System Status, System Category

Page 103 highlights

Unknown Informational • Management Processor: Displays a link to the Remote Insight Lights-Out Edition (RILOE) board or the Integrated Lights-Out (iLO) board. This information is provided by the WBEM Providers. If no WBEM Providers are installed, none displays. The SMH Home Page The Home page provides system, subsystem, and status views of the server. Information on the Home page is provided by the integrated Web-Based Enterprise Management (WBEM) property pages and management utilities. It also includes information provided by integrated version control, server, and storage agents. Overall Status Summary The Overall Status Summary displays links to all subsystems that have a critical, major, minor, or warning status, which the integrated HP Web-enabled System Management software provides. If there are no agents installed or no critical, major, minor or warning items, the Overall Status Summary displays no items. System Status The System Status displays a status icon with a label under it. A specific webapp sets the value of the System Status icon by using a predefined heuristic to signal the system status. When the webapp is not set for use, System Status displays the worst status reported in the Overall Status Summary box. System Category The System category presents the system hardware WBEM information. The first link is a System Summary that includes the system's identity information and health status. This health status is also propagated to the HP Systems Insight Manager (HP SIM). In addition to the summary, links show status and other information about subsystems, such as memory and processors. The System category displays the following information: • Cooling and temperature: Provides information about the device environment, including thermal and fan status, temperature sensor condition, sensor location, current temperature, temperature threshold, type of threshold, and fan information. • Memory: Provides information about memory modules, including index, location, description, HP serial number, and HP part number. • Power: Provides information about power supply groups, including location, presence, status, redundancy state, used capacity, hot pluggable, model, maximum capacity, serial number, voltage, firmware revision, and group redundancy. • Processors: Provides processor details, including cabinet number, cell number, socket, number of cores, threading status, processor type and speed, revision level, numeric coprocessor, cache amount, maximum speed, serial number, part number, total available cache, and number of active logical processors. • FRU information: Provides information about Field Replaceable Units in the system, including index, name, part number, vendor, type, serial number, class, slot number, chassis number, I/O chassis number, and asset number. • I/O chassis: Provides I/O chassis information, including power state and the identity of each device installed in the PCI expansion slots. Using SMH 103

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

Unknown
Informational
Management Processor: Displays a link to the Remote Insight Lights-Out Edition (RILOE)
board or the Integrated Lights-Out (iLO) board. This information is provided by the WBEM
Providers. If no WBEM Providers are installed,
none
displays.
The SMH Home Page
The Home page provides system, subsystem, and status views of the server. Information on the
Home page is provided by the integrated Web-Based Enterprise Management (WBEM) property
pages and management utilities. It also includes information provided by integrated version
control, server, and storage agents.
Overall Status Summary
The Overall Status Summary displays links to all subsystems that have a critical, major, minor,
or warning status, which the integrated HP Web-enabled System Management software provides.
If there are no agents installed or no critical, major, minor or warning items, the Overall Status
Summary displays
no items
.
System Status
The System Status displays a status icon with a label under it. A specific webapp sets the value
of the System Status icon by using a predefined heuristic to signal the system status. When the
webapp is not set for use, System Status displays the worst status reported in the Overall Status
Summary box.
System Category
The System category presents the system hardware WBEM information. The first link is a System
Summary that includes the system's identity information and health status. This health status is
also propagated to the HP Systems Insight Manager (HP SIM). In addition to the summary, links
show status and other information about subsystems, such as memory and processors. The
System category displays the following information:
Cooling and temperature: Provides information about the device environment, including
thermal and fan status, temperature sensor condition, sensor location, current temperature,
temperature threshold, type of threshold, and fan information.
Memory: Provides information about memory modules, including index, location, description,
HP serial number, and HP part number.
Power: Provides information about power supply groups, including location, presence,
status, redundancy state, used capacity, hot pluggable, model, maximum capacity, serial
number, voltage, firmware revision, and group redundancy.
Processors: Provides processor details, including cabinet number, cell number, socket,
number of cores, threading status, processor type and speed, revision level, numeric
coprocessor, cache amount, maximum speed, serial number, part number, total available
cache, and number of active logical processors.
FRU information: Provides information about Field Replaceable Units in the system, including
index, name, part number, vendor, type, serial number, class, slot number, chassis number,
I/O chassis number, and asset number.
I/O chassis: Provides I/O chassis information, including power state and the identity of each
device installed in the PCI expansion slots.
Using SMH
103