Diagnostic Error Codes, Fixed disk drive/ Run DIAGNOSTICS.
View all HP Portable 386 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
304 - Keyboard or None Keyboard or 1. Replace keyboard. System Unit Error system board 2. Replace system board. failure 401 - Printer None System board Replace system board. Interface Error failure 402 - Monochrome 1 Long, System board or 1. Replace plasma display Adapter Error 2 Short plasma display controller board controller board 2. Replace system board failure 501 - Display 1 Long, Plasma display or 1. Replace plasma display Adapter Failure 2 Short plasma display controller board. controller board 2. Replace plasma display 601 - Diskette None System board Replace system board. Controller Error failure 701 - Coprocessor None Coprocessor Replace coprocessor. Error Error 702 - Coprocessor None Coprocessor 1. Check jumper setting. Detection Error installation 2. Replace coprocessor. Message Beeps Probable Cause Recommended Action 1780 - Disk 0 None Fixed disk drive/ Run DIAGNOSTICS. Failure format error 1782 - Disk None Fixed disk drive Run DIAGNOSTICS. Controller Failure controller error 1790 - Disk 0 None Fixed disk drive 1. Run SETUP. Failure 2. Run DIAGNOSTICS. Parity Check 2 None Expansion RAM Run DIAGNOSTICS. XX000 Y ZZ failure Audible 1 Short Power on None. successful Audible 2 Short Power on None. successful (RESUME ="F1" KEY) None As indicated on Press F1 key. display Chapter 6.3 Diagnostic Error Codes DIAGNOSTIC error codes occur if the system recognizes a problem while running the COMPAQ DIAGNOSTICS Program. These error codes help identify possible defective subassemblies. Tables 6-2 through 6-13 list possible error codes, a description of the error condition, and the action required to resolve the error condition. In each case, the Recommended Action column lists steps necessary to correct