HP Portable 386 Compaq Portable 386 Personal Computer Maintenance and Service - Page 44
xx Fixed Disk Drive Conditional, Switch Settings.
View all HP Portable 386 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Error Code Error Description Recommended Action 1716 - xx Fixed Disk Drive Conditional The following steps apply to error Format Test codes 1700 - xx through 1717 - 73: 1716 - 01 Exceeded maximum soft error limit. 1716 - 02 Exceeded maximum hard error limit. 1716 - 05 Failed to reset controller. 1716 - 06 Fatal error while reading. 1716 - 07 Fatal error while writing. 1. Check the system board jumper settings and retest (see Chapter 9, "Jumper and Switch Settings"). 2. Replace the fixed disk drive signal and power cables and retest. 3. Replace the fixed disk drive and retest. 4. Replace the system board and retest. 1716 - 08 Failed compare of write/ read buffers. 1716 - 09 Failed to format a cylinder. 1716 - 40 Cylinder 0 failed. 1716 - 42 Failed recalibrate. 1716 - 55 Cylinder 1 error. 1716 - 58 Failed to write sector buffer. Error Code Error Description Recommended Action 1716 - 59 Failed to read sector The following steps apply to error buffer. codes 1700 - xx through 1717 - 73: 1716 - 60 Failed to compare sector buffer. 1716 - 65 Exceeded maximum bad sector per track. 1716 - 66 Failed to initialize drive parameter. 1716 - 70 Failed translate mode. 1716 - 71 Failed nontranslate mode. 1. Check the system board jumper settings and retest (see Chapter 9, "Jumper and Switch Settings"). 2. Replace the fixed disk drive signal and power cables and retest. 3. Replace the fixed disk drive and retest. 4. Replace the system board and retest. 1716 - 72 Exceeded maximum bad track limit. 1716 - 73 Previously exceeded maximum bad track limit.