HP Portable 386 Compaq Portable 386 Personal Computer Maintenance and Service - Page 44

xx Fixed Disk Drive Conditional, Switch Settings.

Page 44 highlights

Error Code Error Description Recommended Action 1716 - xx Fixed Disk Drive Conditional The following steps apply to error Format Test codes 1700 - xx through 1717 - 73: 1716 - 01 Exceeded maximum soft error limit. 1716 - 02 Exceeded maximum hard error limit. 1716 - 05 Failed to reset controller. 1716 - 06 Fatal error while reading. 1716 - 07 Fatal error while writing. 1. Check the system board jumper settings and retest (see Chapter 9, "Jumper and Switch Settings"). 2. Replace the fixed disk drive signal and power cables and retest. 3. Replace the fixed disk drive and retest. 4. Replace the system board and retest. 1716 - 08 Failed compare of write/ read buffers. 1716 - 09 Failed to format a cylinder. 1716 - 40 Cylinder 0 failed. 1716 - 42 Failed recalibrate. 1716 - 55 Cylinder 1 error. 1716 - 58 Failed to write sector buffer. Error Code Error Description Recommended Action 1716 - 59 Failed to read sector The following steps apply to error buffer. codes 1700 - xx through 1717 - 73: 1716 - 60 Failed to compare sector buffer. 1716 - 65 Exceeded maximum bad sector per track. 1716 - 66 Failed to initialize drive parameter. 1716 - 70 Failed translate mode. 1716 - 71 Failed nontranslate mode. 1. Check the system board jumper settings and retest (see Chapter 9, "Jumper and Switch Settings"). 2. Replace the fixed disk drive signal and power cables and retest. 3. Replace the fixed disk drive and retest. 4. Replace the system board and retest. 1716 - 72 Exceeded maximum bad track limit. 1716 - 73 Previously exceeded maximum bad track limit.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

Error
Code
Error Description
Recommended Action
------------------------------------------------------------------------------
1716 - xx Fixed Disk Drive Conditional
The following steps apply to error
Format Test
codes 1700 - xx through 1717 - 73:
1716 - 01 Exceeded maximum soft error
1. Check the system board jumper
limit.
settings and retest
(see Chapter 9, "Jumper and
1716 - 02 Exceeded maximum hard error
Switch Settings").
limit.
2. Replace the fixed disk drive
signal and power cables and
1716 - 05 Failed to reset controller.
retest.
3. Replace the fixed disk drive
1716 - 06 Fatal error while reading.
and retest.
4. Replace the system board and
1716 - 07 Fatal error while writing.
retest.
1716 - 08 Failed compare of write/
read buffers.
1716 - 09 Failed to format a cylinder.
1716 - 40 Cylinder 0 failed.
1716 - 42 Failed recalibrate.
1716 - 55 Cylinder 1 error.
1716 - 58 Failed to write sector
buffer.
------------------------------------------------------------------------------
Error
Code
Error Description
Recommended Action
------------------------------------------------------------------------------
1716 - 59 Failed to read sector
The following steps apply to error
buffer.
codes 1700 - xx through 1717 - 73:
1716 - 60 Failed to compare sector
1. Check the system board jumper
buffer.
settings and retest
(see Chapter 9, "Jumper and
1716 - 65 Exceeded maximum bad sector
Switch Settings").
per track.
2. Replace the fixed disk drive
signal and power cables and
1716 - 66 Failed to initialize drive
retest.
parameter.
3. Replace the fixed disk drive
and retest.
1716 - 70 Failed translate mode.
4. Replace the system board and
retest.
1716 - 71 Failed nontranslate mode.
1716 - 72 Exceeded maximum bad track
limit.
1716 - 73 Previously exceeded maximum
bad track limit.