HP Portable 386 Compaq Portable 386 Personal Computer Maintenance and Service - Page 28
Table 6-4. Keyboard Error Codes 3xx - xx Range, Walking I/O test failed.
View all HP Portable 386 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
204 - 02 Error during saving program memory in address test. 204 - 03 Error during restore of program memory in address test. 204 - 04 A20 address test failed. Error Code Error Description Recommended Action 204 - 05 Page hit address test failed. Replace the appropriate memory module(s) or memory board and 205 - 01 Walking I/O test failed. retest for error codes 203 - 01 through 210 - 03. Refer to 205 - 02 Error during saving program Section 6.4. memory in walking I/O test. 205 - 03 Error during restore of program memory in walking I/O test. 205 - 04 Insufficient memory to perform test. 208 - 01 Memory refresh test failed. 208 - 02 Error during saving program memory in refresh test. 208 - 03 Error during restore of program memory in refresh test. 210 - xx Random Pattern Test 210 - 01 Random pattern test failed. 210 - 02 Error during saving program. 210 - 03 Error while restore of program Table 6-4. Keyboard Error Codes (3xx - xx Range) Error Code Error Description Recommended Action 301 - 01 Keyboard short test, The following steps apply to error 8042 self test failed. codes 301 - 01 through 304 - 06. 301 - 02 Keyboard short test, interface test failed. 301 - 03 Keyboard short test, echo test failed 301 - 04 Keyboard short test, keyboard retest failed. 1. Check the keyboard connector. If disconnected, turn off the computer and connect the keyboard. 2. Replace the keyboard and retest. 3. Replace the system board and retest. 302 - 01 Keyboard long test failed.