xx Modem Direct Connect Test
View all HP Portable 386 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
retry limit. 1205 - 04 RCV exceeded carrier lost limit. 1205 - 05 XMIT exceeded carrier lost limit. 1205 - 06 Time out waiting for dial tone. 5. Replace the system board and retest. 1205 - 07 Dial number string too long. 1205 - 08 Modem timed out waiting for remote response. 1205 - 09 Modem exceeded maximum redial limit. Error Code Error Description Recommended Action 1205 - 10 Line quality prevented The following steps apply to error remote connection. codes 1201 - 01 through 1210 - 11: 1205 - 11 Modem timed out waiting for 1. Check the jumper settings on remote connection. the system board (see Chapter 9, "Jumper and Switch Settings"). 1206 - xx Dial Multifrequency Tone Test 2. Check the modem connection to the 32 bit memory/modem 1206 - 17 Tone detection failed. interface board. 3. Replace the modem and retest. 1210 - xx Modem Direct Connect Test 4. Replace the 32 bit memory/modem interface board and retest. 1210 - 01 Modem timed out waiting for 5. Replace the system board and SYNC. retest. 1210 - 02 Modem timed out waiting for response. 1210 - 03 Modem exceeded data block retry limit. 1210 - 04 RCV exceeded carrier lost limit. 1210 - 05 XMIT exceeded carrier lost limit. 1210 - 06 Time out waiting for dial tone. 1210 - 07 Dial number string too long. 1210 - 08 Modem timed out waiting for remote response.