HP Portable 386 Compaq Portable 386 Personal Computer Maintenance and Service - Page 34
Table 6-10. Modem Communications Error Codes 12xx - xx Range, 07 UART DATA READY bit failed.
View all HP Portable 386 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Code Error Description Recommended Action 1101 - xx Asynchronous Communications The following steps apply to Interface Test error codes 1101 - xx: 1101 - 01 UART DLAB bit failed. 1101 - 02 Line input or UART fault. 1101 - 03 Address line fault. 1101 - 04 Data line fault. 1101 - 05 UART control signal failed. 1. Check the switch settings on the Serial/Parallel Interface Board, if applicable. 2. Check the jumper settings on the system board. 3. Replace the Serial/Parallel Interface Board, if applicable. 4. Replace the system board and retest. 1101 - 06 UART THRE bit failed. 1101 - 07 UART DATA READY bit failed. 1101 - 08 UART TX/RX buffer failed. 1101 - 09 Interrupt circuit failed. 1101 - 10 COM1 set to interrupt 3. 1101 - 11 COM2 set to interrupt 4. 1101 - 12 Drive/receiver control signal failed. 1101 - 13 UART control signal interrupt failed. 1101 - 14 Drive/receiver data failed. Error Code Error Description Recommended Action 1109 - 01 Clock register The following steps apply to error initialization failed. 1109 - xx: 1109 - 02 Clock register rollover failed. 1109 - 03 Clock reset failed. 1109 - 04 Input line or clock failed. 1. Check the jumper settings on the system board (see Chapter 9, "Jumper and Switch Settings"). 2. Replace the system board and retest. 1109 - 05 Address line fault. 1109 - 06 Data line fault Table 6-10. Modem Communications Error Codes (12xx - xx Range