HP Portable 386 Compaq Portable 386 Personal Computer Maintenance and Service - Page 39
xx Fixed Disk Drive Read Test
View all HP Portable 386 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
1701 - 59 Failed to read sector buffer. 1701 - 66 Failed to initialize fixed disk drive parameter. and retest. 4. Replace the system board and retest. 1702 - xx Fixed Disk Drive Read Test 1702 - 01 Exceeded maximum soft error limit. 1702 - 02 Exceeded maximum hard error limit. 1702 - 03 Previously exceeded maximum soft error limit. 1702 - 04 Previously exceeded maximum hard error limit. Error Code Error Description Recommended Action 1702 - 05 Failed to reset controller The following steps apply to error codes 1700 - xx through 1717 - 73: 1702 - 06 Fatal error while reading 1. Check the system board jumper 1702 - 40 Failed cylinder 0. settings and retest (see Chapter 9, "Jumper and 1702 - 65 Exceeded maximum bad sector Switch Settings"). per track. 2. Replace the fixed disk drive signal and power cables and 1702 - 68 Failed to read long. retest. 3. Replace the fixed disk drive 1702 - 70 Failed to translate mode. and retest. 4. Replace the system board and 1702 - 71 Failed nontranslated mode. retest. 1702 - 72 Exceeded maximum bad track limit. 1702 - 73 Previously exceeded maximum bad track limit. 1703 - xx Fixed Disk Drive Write/Read/ Compare Test 1703 - 01 Exceeded maximum soft error limit. Error Code Error Description Recommended Action 1703 - 02 Exceeded maximum hard error The following steps apply to error limit. codes 1700 - xx through 1717 - 73: 1703 - 03 Previously exceeded maximum 1. Check the system board jumper