HP Portable 386 Compaq Portable 386 Personal Computer Maintenance and Service - Page 50

Table 6-14. COMPAQ Dual Mode Plasma Display Error Codes 51xx - xx Range, 01 VGC and ECG ROM checksum

Page 50 highlights

2414 - 01 Video White Screen Test 2416 - 01 Video Noise Pattern Test Error Code Error Description Recommended Action 2417 - 01 Lightpen text mode test The following steps apply to error failed; no response. codes 2417 - xx. 2417 - 02 Lightpen text mode test 1. Check the switch settings on failed; invalid response. the video board (see Chapter 9, "Jumper and Switch Settings"). 2417 - 03 Lightpen medium resolution 2. Replace the lightpen and mode test failed; no response. retest. 3. Replace the video board and 2417 - 04 Lightpen medium resolution retest. mode test failed; invalid 4. Replace the system board and response. retest. Error Code Error Description Recommended Action 2418 - 01 VGC memory test failed. The following steps apply to error codes 2418 - xx through 2425 - xx. 2418 - 02 VGC and ECG shadow RAM test failed. 1. Verify the switch settings. 2. Replace the video board and 2419 - 01 VGC and ECG ROM checksum retest. test failed. 3. Replace the system board and retest. 2420 - 01 VGC and ECG attribute test failed. 2421 - 01 VGC and ECG 640 x 200 graphics mode test failed. 2422 - 01 VGC and ECG 640 x 350 16 color set test failed. 2423 - 01 VGC and ECG 640 x 350 64 color set test failed. 2424 - 01 VGC and ECG monochrome text mode test failed. 2425 - 01 VGC and ECG monochrome graphics mode test failed. Table 6-14. COMPAQ Dual Mode Plasma Display Error Codes (51xx - xx Range) Error Code Error Description Recommended Action 5101 - 01 Video controller Test The following steps apply to error codes 5101 - 01 through 5129 - 01: 5102 - 01 Video Memory Test

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

2414 - 01 Video White Screen Test
2416 - 01 Video Noise Pattern Test
------------------------------------------------------------------------------
Error
Code
Error Description
Recommended Action
------------------------------------------------------------------------------
2417 - 01 Lightpen text mode test
The following steps apply to error
failed; no response.
codes 2417 - xx.
2417 - 02 Lightpen text mode test
1. Check the switch settings on
failed; invalid response.
the video board (see Chapter 9,
"Jumper and Switch Settings").
2417 - 03 Lightpen medium resolution
2. Replace the lightpen and
mode test failed; no response.
retest.
3. Replace the video board and
2417 - 04 Lightpen medium resolution
retest.
mode test failed; invalid
4. Replace the system board and
response.
retest.
------------------------------------------------------------------------------
Error
Code
Error Description
Recommended Action
------------------------------------------------------------------------------
2418 - 01 VGC memory test failed.
The following steps apply to error
codes 2418 - xx through 2425 - xx.
2418 - 02 VGC and ECG shadow RAM test
failed.
1. Verify the switch settings.
2. Replace the video board and
2419 - 01 VGC and ECG ROM checksum
retest.
test failed.
3. Replace the system board and
retest.
2420 - 01 VGC and ECG attribute test
failed.
2421 - 01 VGC and ECG 640 x 200
graphics mode test failed.
2422 - 01 VGC and ECG 640 x 350
16 color set test failed.
2423 - 01 VGC and ECG 640 x 350
64 color set test failed.
2424 - 01 VGC and ECG monochrome
text mode test failed.
2425 - 01 VGC and ECG monochrome
graphics mode test failed.
==============================================================================
Table 6-14. COMPAQ Dual Mode Plasma Display Error Codes (51xx - xx Range)
==============================================================================
Error
Code
Error Description
Recommended Action
------------------------------------------------------------------------------
5101 - 01 Video controller Test
The following steps apply to error
codes 5101 - 01 through 5129 - 01:
5102 - 01 Video Memory Test