JVC GY-HM620U Instruction Manual - Page 61

Automatic White Balance Mode FAW, Fulltime Auto White balance, White Paint Adjustment

Page 61 highlights

Shooting White Paint Adjustment You can fine-tune the white balance saved in Memory A or Memory B. 1 Select [Main Menu] B [Camera Process] B [White Balance] B [AWB Paint] and press the Set button (R). The White Paint Adjustment screen appears. 1 Automatic White Balance Mode (FAW: Fulltime Auto White balance) 0 Press the [WHT BAL] button on the side control panel to enter into Automatic White Balance mode. 0 "" appears on the screen. 0 Set the [FULL AUTO] switch on the camera recorder to "ON" to enter Automatic White Balance mode. An appropriate white balance is automatically adjusted according to the color temperature of the lighting on the object. 0 White balance switching with the [WHT BAL B/A/PRESET] selection switch is disabled. . 2 Adjust the R and B values. Use the cross-shaped button (JK) to adjust R value and (HI) to adjust B value. . 3 Press the Set button (R). Returns to the [White Balance] screen. R Value B Value 00: 00: 00.00 Jan 12,2016 12 :34 : 56 4030 20 10 0 FAW 5.6f t ND 1 /64 AE+6 0dB F1. 6 1/ 100 FAW . Caution : 0 The accuracy of [FAW] is inferior to that of Auto White Balance. 0 When the power of the camera recorder is turned on with the [FAW] mode selected, it takes about 15 seconds for the colors to stabilize. Memo : 0 When [Main Menu] B [Camera Function] B [User Switch Set] B [AE Lock] is set to "AE/WB", the white balance when the user button that is assigned [AE Lock] is pressed can be fixed. (A P101 [ AE Lock ] ) 0 If [White Balance] has been assigned to the user button, pressing the assigned user button will display the FAW Paint Adjustment screen. (A P38 [Assignment of Functions to User Buttons] ) . Memo : 0 Selecting [y] will usually clear the White Paint Adjustment value. But when [Main Menu] B [Camera Process] B [White Balance] B [Clear Paint After AWB] is set to "Off", values will not be cleared even when [y] is selected. (A P106 [ Clear Paint After AWB ] ) 0 If [White Balance] has been assigned to the user button, pressing the assigned user button will display the AWB Paint Adjustment screen. (A P38 [Assignment of Functions to User Buttons] ) 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

White Paint Adjustment
You can fine-tune the white balance saved in
Memory A or Memory B.
1
Select [Main Menu]
B
[Camera Process]
B
[White Balance]
B
[AWB Paint] and press
the Set button (
R
).
The White Paint Adjustment screen appears.
.
1
2
Adjust the R and B values.
Use the cross-shaped button (
JK
) to adjust R
value and (
HI
) to adjust B value.
.
3
Press the Set button (
R
).
Returns to the [White Balance] screen.
.
B Value
R Value
Memo :
0
Selecting [
y
] will usually clear the White Paint
Adjustment value. But when [Main Menu]
B
[Camera Process]
B
[White Balance]
B
[Clear
Paint After AWB] is set to “Off”, values will not
be cleared even when [
y
] is selected.
(
A
P106 [ Clear Paint After AWB ] )
0
If [White Balance] has been assigned to the user
button, pressing the assigned user button will
display the AWB Paint Adjustment screen.
(
A
P38 [Assignment of Functions to User
Buttons] )
Automatic White Balance Mode (FAW:
Fulltime Auto White balance)
0
Press the [WHT BAL] button on the side control
panel to enter into Automatic White Balance
mode.
0
“<FAW>” appears on the screen.
0
Set the [FULL AUTO] switch on the camera
recorder to “ON” to enter Automatic White
Balance mode. An appropriate white balance is
automatically adjusted according to the color
temperature of the lighting on the object.
0
White balance switching with the [WHT BAL
B/A/PRESET] selection switch is disabled.
.
1/ 100
F1.6
0
dB
AE
+
6
ND 1 /64
12:34:56
Jan 12,2016
00:00:00.00
4030 20
10
0
5.6ft
FAW
FAW
Caution :
0
The accuracy of [FAW] is inferior to that of Auto
White Balance.
0
When the power of the camera recorder is
turned on with the [FAW] mode selected, it takes
about 15 seconds for the colors to stabilize.
Memo :
0
When [Main Menu]
B
[Camera Function]
B
[User
Switch Set]
B
[AE Lock] is set to “AE/WB”, the
white balance when the user button that is
assigned [AE Lock] is pressed can be fixed.
(
A
P101 [ AE Lock ] )
0
If [White Balance] has been assigned to the user
button, pressing the assigned user button will
display the FAW Paint Adjustment screen.
(
A
P38 [Assignment of Functions to User
Buttons] )
61