JVC GY-HM620U Instruction Manual - Page 71

Setting Zebra Pattern, Settings and Operation of the Camera, Recorder

Page 71 highlights

Shooting Settings and Operation of the Camera Recorder 1 Set to Camera mode. (A P18 [Operation Modes] ) 2 Set [TC/UB] B [TC Generator] as follows. 0 Slave device: Select "Free Run(Ext)". 0 Master device: Select "Free Run". 3 Set LCD monitor or viewfinder to Display 1 screen. 4 Set the master device and run the time code. 0 When the built-in time code generator is synchronized with the external time code data input, the Z icon on Display 1 screen lights up. 0 When time code is not synchronized or time code input is not available, the Z icon goes out. 00 : 00 : 00.00 Jan 24 ,2012 12 :34 : 56 4030 20 10 0 P13000K 5.6f t ND 1 /64 AE+6 0dB F1. 6 1/ 100 . Memo : 0 The built-in time code generator will continue operation even when the master device is disconnected after synchronization. 0 User's bit will become data in the master device. 0 While the [TC] terminal is connected, the time code may be out of synchronization when the [A/V Set] B [Video Set] B [HDMI/SDI Out] setting of the Master device and Slave device is being changed. (A P112 [ HDMI/SDI Out ] ) Setting Zebra Pattern When the luminance level range for displaying zebra patterns is specified, diagonal lines (zebra pattern) are displayed at areas with the specified luminance levels during shooting. AE LEVEL PUSH AUTO ZEBRA/5 . 1 Set the zebra display pattern. Select the display pattern in [LCD/VF] B [Shooting Assist] B [Zebra]. 2 Specify the brightness (luminance) level range for displaying zebra pattern. Specify the upper and lower limits of the luminance level in [LCD/VF] B [Shooting Assist] B [Zebra] B [Top] and [Bottom]. Item Top Settings Options Upper luminance 5% - 100%, Over limit for displaying (in 5 % increments) [Zebra] Bottom Lower luminance 0% - 100% (in 5 % limit for displaying increments) [Zebra] 3 Display the zebra pattern. Press the [ZEBRA/5] button to display the zebra pattern in the specified range. . During zebra pattern display, (zebra icon) is displayed on the display screen in Camera mode. Memo : 0 "Zebra" is assigned to [ZEBRA/5] button in factory default. 0 "Zebra" can also be assigned to other user buttons. (A P38 [Assignment of Functions to User Buttons] ) 71

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

Settings and Operation of the Camera
Recorder
1
Set to Camera mode.
(
A
P18 [Operation Modes] )
2
Set [TC/UB]
B
[TC Generator] as follows.
0
Slave device:
Select “Free Run(Ext)”.
0
Master device:
Select “Free Run”.
3
Set LCD monitor or viewfinder to Display 1
screen.
4
Set the master device and run the time
code.
0
When the built-in time code generator is
synchronized with the external time code
data input, the
Z
icon on Display 1 screen
lights up.
0
When time code is not synchronized or time
code input is not available, the
Z
icon goes
out.
.
P 13000K
1/ 100
F1.6
0
dB
AE
+
6
ND 1 /64
12:34:56
Jan 24,2012
00:00:00.00
4030 20
10
0
5.6ft
Memo :
0
The built-in time code generator will continue
operation even when the master device is
disconnected after synchronization.
0
User’s bit will become data in the master device.
0
While the [TC] terminal is connected, the time
code may be out of synchronization when the
[A/V Set]
B
[Video Set]
B
[HDMI/SDI Out]
setting of the Master device and Slave device is
being changed.
(
A
P112 [ HDMI/SDI Out ] )
Setting Zebra Pattern
When the luminance level range for displaying
zebra patterns is specified, diagonal lines (zebra
pattern) are displayed at areas with the specified
luminance levels during shooting.
.
ZEBRA/5
1
Set the zebra display pattern.
Select the display pattern in [LCD/VF]
B
[Shooting Assist]
B
[Zebra].
2
Specify the brightness (luminance) level
range for displaying zebra pattern.
Specify the upper and lower limits of the
luminance level in [LCD/VF]
B
[Shooting
Assist]
B
[Zebra]
B
[Top] and [Bottom].
Item
Settings
Options
Top
Upper luminance
limit for displaying
[Zebra]
5% - 100%, Over
(in 5 % increments)
Bottom
Lower luminance
limit for displaying
[Zebra]
0% - 100% (in 5 %
increments)
3
Display the zebra pattern.
Press the [ZEBRA/5] button to display the zebra
pattern in the specified range.
.
During zebra pattern display,
(zebra icon)
is displayed on the display screen in Camera
mode.
Memo :
0
“Zebra” is assigned to [ZEBRA/5] button in
factory default.
0
“Zebra” can also be assigned to other user
buttons.
(
A
P38 [Assignment of Functions to User
Buttons] )