Ricoh SP C250DN Operating Instructions - Page 177
Waste Tnr Bottle Setting Error, Replace Waste Toner Bottle
View all Ricoh SP C250DN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 177 highlights
Error & Status Messages on the Control Panel Message Replace Waste Toner Bottle Tnr Set Error: # Fusing Unit Setting Error Waste Tnr Bottle Setting Error Service call SCXXX Density Sensor Require Cleaning Explanation Recommended Action It is time to replace the waste toner bottle. Replace the waste toner bottle with a new one. See page 134 "Replacing the Waste Toner Bottle". The indicated print cartridge is not installed correctly, or not installed. Install the indicated print cartridge correctly. The error message appears even though the print cartridge is installed correctly. Using a dry cloth, carefully wipe the interface area on the print cartridge surface. The fusing unit is not installed or Install the fusing unit correctly. not installed correctly. The waste toner bottle is not installed or not installed correctly. Install the waste toner bottle correctly. If the error message appears even though the waste toner bottle is attached correctly, contact your service representative. There is a problem with the printer's controller. Turn off the main power, and then turn it on again. If the error occurs again, contact your sales or service representative. Color registration failed. Clean the toner density sensor. See page 142 "Cleaning the Toner Density Sensor". • The message about intermediate transfer unit, fusing unit, and transfer roller appear only for the Type 2 model. 175