Sony SNCEP520 User Manual (SNC-ER/EP User Guide) - Page 75

Periodical sending Tab - Setting the periodical FTP client activity, Remote path, Image file name

Page 75 highlights

Administrating the Camera Remote path Type the path to the destination using up to 64 characters. Image file name Type the file name you want to assign to the images when sending to the FTP server. You can use up to 10 alphanumeric characters, - (hyphen) and _ (underscore) for naming. Suffix Select a suffix to be added to the file name. Date & time: The date & time suffix is added to the image file name. The date/time suffix consists of the year (2 digits), month (2 digits), date (2 digits), hour (2 digits), minute (2 digits) and second (2 digits), and sequential number (2 digits), thus adding a 14-digit number to the image file name. Sequence number: A sequential number of 10 digits between 0000000001 and 4294967295 and a sequential 2-digit number are added to the image file name. Tip A sequential number added to Date & time and Sequence number is used to identify individual files created with consecutive alarm events. Sequence number clear Click Clear to reset the Sequence number suffix to 1. Alarm Select the alarm to be linked with the file to be forwarded to the FTP server. Sensor input 1: The external sensor that is connected to sensor input 1 of the camera I/O port. Sensor input 2: The external sensor that is connected to sensor input 2 of the camera I/O port. Tampering: An alarm that is triggered when the camera detects tampering, such as direction shift or spraying. Motion detection: The alarm detected by the motion detection function. Click Detection, and the Motion detection menu is displayed to allow you to set the motion detection function (page 88). Note In the case that the synchronized preset position is specified in Position at alarm in the Preset position menu, an alarm event that happens when the camera moves to the preset position will be invalid. Effective period Set the period during which alarm detection is effective. Always: Alarm detection is always effective. Schedule: You can specify the period during which alarm detection is effective. Click Schedule and the menu for the effective period is displayed. ("Setting the Schedule - Schedule Menu" on page 87) Alarm buffer Select Use alarm buffer to forward the image/audio at a specified time before or after alarm detection (prealarm, post-alarm). If you do not select the alarm buffer, only the image at the moment of alarm detection is forwarded. Click Alarm buffer to display the Alarm buffer menu. For details, see "Setting the Alarm Buffer - Alarm buffer Menu" on page 88. OK/Cancel See "Buttons common to every menu" on page 35. Periodical sending Tab - Setting the periodical FTP client activity You can set to send image files (JPEG files) to an FTP server periodically. Note When more than two of the following settings are activated, the camera only creates two still images at the same time. A third still image cannot be created unless one of the previous two still images is sent. e-Mail (SMTP) menu - Alarm sending tab Alarm sending (when file attachment is set to On). - Periodical sending Periodical sending FTP client menu - Alarm sending tab Alarm sending - Periodical sending Periodical sending Trigger menu - Mail (SMTP) - FTP Client 75 Sending Images to FTP Server - FTP client Menu

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122

Administrating the Camera
Sending Images to FTP Server — FTP client Menu
75
Remote path
Type the path to the destination using up to 64
characters.
Image file name
Type the file name you want to assign to the images
when sending to the FTP server. You can use up to 10
alphanumeric characters, - (hyphen) and _ (underscore)
for naming.
Suffix
Select a suffix to be added to the file name.
Date & time:
The date & time suffix is added to the
image file name.
The date/time suffix consists of the year (2 digits),
month (2 digits), date (2 digits), hour (2 digits),
minute (2 digits) and second (2 digits), and
sequential number (2 digits), thus adding a 14-digit
number to the image file name.
Sequence number:
A sequential number of 10 digits
between 0000000001 and 4294967295 and a
sequential 2-digit number are added to the image file
name.
Tip
A sequential number added to
Date & time
and
Sequence number
is used to identify individual files
created with consecutive alarm events.
Sequence number clear
Click
Clear
to reset the
Sequence number
suffix to 1.
Alarm
Select the alarm to be linked with the file to be
forwarded to the FTP server.
Sensor input 1:
The external sensor that is connected to
sensor input 1 of the camera I/O port.
Sensor input 2:
The external sensor that is connected to
sensor input 2 of the camera I/O port.
Tampering:
An alarm that is triggered when the camera
detects tampering, such as direction shift or spraying.
Motion detection:
The alarm detected by the motion
detection function.
Click
Detection
, and the Motion detection menu is
displayed to allow you to set the motion detection
function (page 88).
Note
In the case that the synchronized preset position is
specified in
Position at alarm
in the Preset position
menu, an alarm event that happens when the camera
moves to the preset position will be invalid.
Effective period
Set the period during which alarm detection is effective.
Always:
Alarm detection is always effective.
Schedule:
You can specify the period during which
alarm detection is effective.
Click
Schedule
and the menu for the effective period
is displayed. (“Setting the Schedule — Schedule
Menu” on page 87)
Alarm buffer
Select
Use alarm buffer
to forward the image/audio at
a specified time before or after alarm detection (pre-
alarm, post-alarm).
If you do not select the alarm buffer, only the image at
the moment of alarm detection is forwarded.
Click
Alarm buffer
to display the Alarm buffer menu.
For details, see “Setting the Alarm Buffer — Alarm
buffer Menu” on page 88.
OK/Cancel
See “Buttons common to every menu” on page 35.
Periodical sending Tab — Setting
the periodical FTP client activity
You can set to send image files (JPEG files) to an FTP
server periodically.
Note
When more than two of the following settings are
activated, the camera only creates two still images at the
same time. A third still image cannot be created unless
one of the previous two still images is sent.
e-Mail (SMTP) menu
– Alarm sending tab
Alarm sending
(when file
attachment is set to On).
– Periodical sending
Periodical sending
FTP client menu
– Alarm sending tab
Alarm sending
– Periodical sending
Periodical sending
Trigger menu
Mail (SMTP)
FTP Client