Brother International MFC 8500 Service Manual - Page 169
WSW01, Dial pulse setting, Selectors 1 and 2, Dial pulse generation mode
UPC - 012502603832
View all Brother International MFC 8500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 169 highlights
Selector No. 1 2 3 4 5 6 7 8 WSW01 (Dial pulse setting) Function Dial pulse generation mode Break time length in pulse dialing Inter-digit pause Switching between pulse (DP) and tone (PB) dialing, by the function switch Default dialing mode, pulse (DP) or tone (PB) dialing Setting and Specifications No. 1 2 00 : 01 : 10 : 11 : No. 3 4 00 : 01 : 10 : 11 : No. 5 6 00 : 01 : 10 : 11 : N N+1 10-N N 60 ms 67 ms 40 ms (for 16 PPS) 64 ms (at 106-ms intervals) 800 ms 850 ms 950 ms 600 ms 0: Yes 1: No 0: PB 1: DP NOTE: In models supporting no pulse (DP) dialing mode (e.g., U.S.A. version), selector 7 takes no effect even if it may be set. Selectors 1 and 2: Dial pulse generation mode These selectors set the number of pulses to be generated in pulse dialing. N: Dialing "N" generates "N" pulses. (Dialing "0" generates 10 pulses.) N + 1: Dialing "N" generates "N + 1" pulses. 10 - N: Dialing "N" generates "10 - N" pulses. Selectors 3 and 4: Break time length in pulse dialing These selectors set the break time length in pulse dialing. (Example: If "1," "2," and "3" are dialed when N is set by selectors 1 and 2.) Selectors 5 and 6: Inter-digit pause These selectors set the inter-digit pause in pulse dialing. (Example: If "1," "2," and "3" are dialed when N is set by selectors 1 and 2.) 2