Brother International MFC 8500 Service Manual - Page 194
Selectable from the range of 0-15, OGM to the line
UPC - 012502603832
View all Brother International MFC 8500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 194 highlights
Selector No. 1 2 3 4 5 | 8 WSW24 (TAD setting 2) Function Setting and Specifications Not used. Time length from CML ON to start of pseudo ring backtone transmission Attenuator for playback of ICM/ OGM to the line (Selectable from the range of 0-15 dB) No. 3 4 0 0 : 4 sec. 0 1 : 3 sec. 1 0 : 2 sec. 1 1 : 1 sec. 0: 0 dB 0: 0 dB 0: 0 dB 0: 0 dB 1: 8 dB 1: 4 dB 1: 2 dB 1: 1 dB Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission These selectors set the length of time from CML-ON up to the start of pseudo ring backtone transmission. In those versions which have an OGM facility, the settings made by these selectors also apply to the length of time from CML-ON up to the start of OGM transmission. Selectors 5 through 8: Attenuator for playback of ICM/OGM to the line Setting two or more selectors to "1" produces addition of attenuation assigned to each selector. This setting will not be limited by selector 8 of WSW23. 27