be accessed by the function switch.
UPC - 012502603832
View all Brother International MFC 8500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 173 highlights
Selector No. 1 2 | 4 5 6 7 8 WSW04 (TRANSFER facility setting) Function Earth function in transfer facility Setting and Specifications 0: Provided 1: Not provided Not used. Earth time length for earth function Break time length for flash function No. 5 6 00 01 10 11 No. 7 8 00 01 10 11 : 200 ms : 300 ms : 500 ms : 700 ms : 80 ms : 110 ms : 250 ms : 500 ms NOTE: Selectors 5 through 8 are not applicable in those countries where no transfer facility is supported. Selector 1: Earth function in transfer facility This selector determines whether or not the earth function is added to the transfer setting menu to be accessed by the function switch. Selectors 5 and 6: Earth time length for earth function These selectors set the short-circuiting time length of the telephone line (La or Lb) to ground. This setting is effective only when the earth function is selected for the R key by using the function switch. Selectors 7 and 8: Break time length for flash function These selectors set the break time length. This setting is effective only when the flash function is selected for the R key by using the function switch. 6