Brother International MFC 8500 Service Manual - Page 202

WSW34, being called, the equipment will no longer detect a CNG signal.

Page 202 highlights

Selector No. 1 | 3 4 5 6 7 8 WSW34 (Function setting 12) Function Setting and Specifications Not used. No. of CNG cycles to be detected No. 4 5 (when the line is connected via the facsimile equipment in the F/T mode 0 0 : 0.5 01 : 1 or via the external telephone in the 1 0 : 1.5 external TAD mode) 11 : 2 No. 6 7 Number of DTMF tone signals for 00: 3 inhibiting the detection of CNG 01: 2 during external TAD operation 10: 1 1 1 : OFF CNG detection when the external telephone is connected with a line in TAD mode 0: Only when the equipment detects itself being called (A) (B) (C) (D) 1: Always NOTE: Selectors 4 and 5 are not applicable to the American version. Selectors 4 and 5: No. of CNG cycles to be detected The equipment interprets a CNG as an effective signal if it detects a CNG signal by the number of cycles specified by these selectors when the line is connected via the facsimile equipment in the F/T mode or via the external telephone in the external TAD mode. Selectors 6 and 7: Number of DTMF tone signals for inhibiting the detection of CNG during external TAD operation If the equipment receives this specified number of DTMF tone signals during external TAD operation, then it will not detect CNG afterwards. If these selectors are set to "1, 1," the CNG detection will not be inhibited. Selector 8: CNG detection when the external telephone is connected with a line in TAD mode If this selector is set to "0," the equipment will detect a CNG signal only when it detects itself being called. If the external telephone is connected with a line before the equipment detects itself being called, the equipment will no longer detect a CNG signal. If this selector is set to "1," the equipment will detect a CNG signal every time the external telephone is connected with a line, even without detecting itself being called. Selector No. 1 | 8 Not used. WSW35 (Function setting 13) Function Setting and Specifications 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239

35
WSW34
(Function setting 12
)
Selector
No.
Function
Setting and Specifications
1
|
3
Not used.
4
5
No. of CNG cycles to be detected
(when the line is connected via the
facsimile equipment in the F/T mode
or via the external telephone in the
external TAD mode)
No. 4
5
0
0
:
0.5
(A)
0
1
:
1
(B)
1
0
:
1.5
(C)
1
1
:
2
(D)
6
7
Number of DTMF tone signals for
inhibiting the detection of CNG
during external TAD operation
No. 6
7
0
0
:
3
0
1
:
2
1
0
:
1
1
1
:
OFF
8
CNG detection when the external
telephone is connected with a line in
TAD mode
0:
Only when the
1: Always
equipment detects
itself being called
NOTE:
Selectors 4 and 5 are not applicable to the American version.
±
Selectors 4 and 5:
No. of CNG cycles to be detected
The equipment interprets a CNG as an effective signal if it detects a CNG signal by the number of
cycles specified by these selectors when the line is connected via the facsimile equipment in the
F/T mode or via the external telephone in the external TAD mode.
±
Selectors 6 and 7:
Number of DTMF tone signals for inhibiting the detection of CNG during external
TAD operation
If the equipment receives this specified number of DTMF tone signals during external TAD
operation, then it will not detect CNG afterwards.
If these selectors are set to "1, 1," the CNG detection will not be inhibited.
±
Selector 8:
CNG detection when the external telephone is connected with a line in TAD mode
If this selector is set to "0," the equipment will detect a CNG signal only when it detects itself
being called. If the external telephone is connected with a line before the equipment detects itself
being called, the equipment will no longer detect a CNG signal.
If this selector is set to "1," the equipment will detect a CNG signal every time the external
telephone is connected with a line, even without detecting itself being called.
WSW35
(Function setting 13)
Selector
No.
Function
Setting and Specifications
1
|
8
Not used.