1.20 NCU Shield and NCU PCB (1) Remove three screws from the NCU shield, then take off the NCU shield. Taptite, cup S M3x6 (Tightening torque: 0.5 N•m) (2) USA version: Disconnect the main-NCU harness from the main PCB. European version: Disconnect the main-NCU harness and main-NCU harness 2 from the main PCB. See the illustration given on the next page. (3) Remove the screw from the NCU PCB and take out the PCB. IV - 48
IV
- 48
1.20
NCU Shield and NCU PCB
(1)
Remove three screws from the NCU shield, then take off the NCU shield.
(2)
USA version: Disconnect the main-NCU harness from the main PCB.
European version: Disconnect the main-NCU harness and main-NCU harness 2 from the main
PCB.
See the illustration given on the next page.
(3)
Remove the screw from the NCU PCB and take out the PCB.
Taptite, cup S M3x6
(Tightening torque: 0.5 N
•