Monitoring the PC ON/OFF state, Monitor both SELECT IN

Page 213 highlights

Selector No. 1 2 3 4 | 8 WSW46 (Monitor of power ON/OFF state and parallel port kept at high) Function Setting and Specifications Monitoring the PC ON/OFF state Parallel port output pins kept at high level No. 1 2 00 : 01 : 10 : 11 : Disabled Monitor SELECT IN Monitor STROBE Monitor both SELECT IN and STROBE Not used. NOTE: Selector 3 is applicable only to models equipped with a parallel interface. l Selectors 1 and 2: Monitoring the PC ON/OFF state For the related functions, refer to WSW36, selectors 2 and 3. l Selector 3: Parallel port output pins kept at high level Setting this selector to "0" will keep all parallel output pints of the facsimile equipment at high level. Use this setting if Resource Manager (bundled with MFC models) installed to WindowsNT running on the connected PC fails to monitor the power ON/OFF state of the facsimile equipment. 46

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239

46
WSW46
(Monitor of power ON/OFF state and parallel port kept at high)
Selector
No.
Function
Setting and Specifications
1
2
Monitoring the PC ON/OFF state
No.
12
00
:
Disabled
0
1
:
Monitor SELECT IN
1
0
:
Monitor STROBE
1
1
:
Monitor both SELECT IN and
STROBE
3
Parallel port output pins kept at high
level
4
|
8
Not used.
NOTE:
Selector 3 is applicable only to models equipped with a parallel interface.
l
Selectors 1 and 2:
Monitoring the PC ON/OFF state
For the related functions, refer to WSW36, selectors 2 and 3.
l
Selector 3:
Parallel port output pins kept at high level
Setting this selector to "0" will keep all parallel output pints of the facsimile equipment at high
level. Use this setting if Resource Manager (bundled with MFC models) installed to WindowsNT
running on the connected PC fails to monitor the power ON/OFF state of the facsimile equipment.