Brother International MFC 8500 Service Manual - Page 186
No redialing
UPC - 012502603832
View all Brother International MFC 8500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 186 highlights
Selector No. 1 2 3 | 6 7 8 WSW15 (REDIAL facility setting) Function Selection of redial interval No. of redialings Redialing for no response sent from the called terminal Not used. Setting and Specifications No. 1 0 0 1 1 No. 3 0 0 0 0 1 2 0: 1: 0: 1: 45 00 00 01 01 | 11 5 minutes 1 minute 2 minutes 3 minutes 6 0 : 16 times 1 : 1 times 0 : 2 times 1 : 3 times | 1 : 15 times 0: Redialing 1: No redialing NOTE: Selector 7 is not applicable in those countries where no busy tone detection is supported. Selectors 1 through 6: Selection of redial interval and No. of redialings The equipment redials by the number of times set by selectors 3 through 6 at intervals set by selectors 1 and 2. This setting is effective only when selector 7 is set to "0." Selectors 7: Redialing for no response sent from the called terminal This selector determines whether or not the equipment redials if no G3 command response comes from the called station after dialing within the time length set by selectors 7 and 8 of WSW09. 19