If the failure of the heat-fixing unit is caused by an opening of the thermistor circuit that senses
UPC - 012502603832
View all Brother International MFC 8500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
(24) Remove the screw and take off the actuator holder. Then unhook end "A" of the ejection actuator spring 2 from the upper FU frame and pull up the ejection actuator 2 together with the spring. Hook Ejection actuator "A" spring 2 Taptite, cup M3x8 Actuator holder Ejection actuator 2 Ejection actuator spring 2 Upper FU frame n Reassembling Notes • A new heat-fixing unit will be provided with the heater thermistor harness being taped to the unit. Before installing the unit, remove the tape. • If you remove and reinstall the heat-fixing unit because of any failure, make the equipment enter the maintenance mode (by pressing the Menu, * 2, 8, 6, and 4 keys) after completion of reassembly and then make it exit from the mode (by pressing the 9 key twice). Otherwise, the heat-fixing unit may not become energized because of the following reason: If the failure of the heat-fixing unit is caused by an opening of the thermistor circuit (that senses the temperature of the heat-fixing unit), then the system misinterprets the hot heater as being cold. As a result, the temperature of the heat-fixing unit may become excessively high. To prevent the system from heating the hot heater further at the next powering-on, it is designed so that the heater will not be energized. To cancel this setting, you need to carry out the above maintenance-mode procedure. IV - 43