HP Surestore 64 fw 05.01.00 and sw 07.01.00 - Director Product Manager - User - Page 215

Switch Binding. The, SANtegrity Binding

Page 215 highlights

Information and Error Messages Table 9: Product Manager Messages (Continued) Message Device applications should be terminated before starting diagnostics. Press NEXT to continue. [device WWN] cannot be removed from the Switch Membership List while participating in Switch Binding. The device must be isolated from the switch, or Switch Binding deactivated before it can be removed. Director clock alert mode must be cleared before enabling period synchronization. Director must be offline to configure. Description Port diagnostics (loopback tests) cannot be performed on a port while an attached device application is running. User attempted to remove a device WWN from the Switch Membership List (SANtegrity Binding feature) while Switch Binding is enabled. Clock alert mode is enabled through the Configure FICON Management Server dialog box and user is attempting to enable Periodic Date/Time Synchronization through the Configure Date and Time dialog box. Clock alert mode is enabled through the Configure FICON Management Server dialog box and user is attempting to enable Periodic Date/Time Synchronization through the Configure Date and Time dialog box. Action Terminate the device application and perform diagnostics again. Remove the device from the switch by blocking the port, setting the switch offline, or disabling Switch Binding through the Switch Binding Change State dialog box before removing devices from the Switch Membership List. Disable clock alert mode through the Configure FICON Management Server dialog box. Disable clock alert mode through the Configure FICON Management Server dialog box. Director Product Manager User Guide 215

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244

Information and Error Messages
215
Director Product Manager User Guide
Device applications
should be terminated
before starting
diagnostics. Press
NEXT to continue.
Port diagnostics
(loopback tests) cannot
be performed on a
port while an attached
device application is
running.
Terminate the device
application and perform
diagnostics again.
[device WWN] cannot
be removed from the
Switch Membership List
while participating in
Switch Binding. The
device must be isolated
from the switch, or
Switch Binding
deactivated before it
can be removed.
User attempted to
remove a device
WWN from the
Switch
Membership List
(SANtegrity Binding
feature) while
Switch
Binding
is enabled.
Remove the device from the
switch by blocking the port,
setting the switch offline, or
disabling
Switch Binding
through the
Switch Binding
Change State
dialog box before
removing devices from the
Switch Membership List
.
Director clock alert
mode must be cleared
before enabling period
synchronization.
Clock alert mode is
enabled through the
Configure FICON
Management Server
dialog box and user is
attempting to enable
Periodic Date/Time
Synchronization
through the
Configure
Date and Time
dialog
box.
Disable clock alert mode
through the
Configure FICON
Management Server
dialog
box.
Director must be offline
to configure.
Clock alert mode is
enabled through the
Configure FICON
Management Server
dialog box and user is
attempting to enable
Periodic Date/Time
Synchronization
through the
Configure
Date and Time
dialog
box.
Disable clock alert mode
through the
Configure FICON
Management Server
dialog
box.
Table 9:
Product Manager Messages (Continued)
Message
Description
Action