HP Surestore 64 fw 05.01.00 and sw 07.01.00 - Director Product Manager - User - Page 39
Set Name As Nickname, Fabric Operating Parameters
View all HP Surestore 64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Product Manager Overview Configure Menu Click the Configure menu on the menu bar to display a menu that lists the following options. For detailed information on using these dialog boxes, refer to Chapter 3, "Configuring the Director." ■ Identification-Choose this option to display the Configure Identification dialog box. Enter the following information in this dialog box: - Name-Assign a product name. Note that you can set this name as the nickname for the director's WWN, using the Set Name As Nickname check box. The nickname then displays instead of the WWN in Product Manager views. - Description-Assign a unique product description. - Location-Describe the product's location. - Contact-Assign a contact either by name, phone number, or e-mail address. Note: This information displays in the identification table at the top of the Hardware View and in the HAFM application Product View, if the Product View is configured to display names. ■ Switch Operating Parameters-Choose this option to display the Configure Switch Parameters dialog box for setting Fibre Channel operating parameters. In this dialog box, you can set the preferred domain identification (1 to 31), and also make it insistent if SANtegrity Binding feature is installed. You can also enable rerouting delay, and domain register for state change notifications (RSCNs). In addition, you can also set the director data speed (Director 2/64 only). The director must be offline to configure director speed and preferred domain ID. ■ Fabric Operating Parameters-Choose this option to display the Configure Fabric Parameters dialog box for setting fabric operating parameters. In this dialog box, you can set buffer-to-buffer credit (BB_Credit) from 1 to 60 (default is 16) and the resource allocation time-out value (R_A_TOV) and error detect time-out value (E_D_TOV) in tenth-of-a-second increments. In addition, you can set the switch priority level (Principal, Default, or Never Principal) and the interoperability modes between Homogeneous, and Open Fabric 1.0. Refer to "Configuring Fabric Parameters" on page 124 for more information on configuring these parameters for the director. The director must be offline to configure any fabric operating parameter. Director Product Manager User Guide 39